A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Computational modeling of nickel-titanium orthopedic staples in the treatment of a fractured scaphoid: Effects of staple bridge configuration. | LitMetric

Internal fixation devices made of nickel-titanium (NiTi) staples have the advantage of producing compressive stress at the fracture site due to their unique shape memory effect and superelasticity. In the present study, a comparison was made between two commercial NiTi staples of the same size but with different bridge configurations, used for scaphoid fracture fixation. The staple and scaphoid anatomical configurations were modeled using SolidWorks, while ABAQUS software was used to analyze the stress and displacement caused by staples and distributed in the scaphoid waist. In the staple with a straight bridge, the regions under the tips of the staple legs underwent the largest stress, whereas there was negligible stress in the regions closer to the staple bridge. In the staple with an S-shaped bridge, the stress concentration was highly localized in the region close to the staple bridge, with a maximum stress that was over eight times higher than in the staple with a straight bridge. Considering the amount and distribution of stress in both staples, neither of the staples was able to create the ideal healing condition on the fracture surface.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2023.105777DOI Listing

Publication Analysis

Top Keywords

staple bridge
12
staple
8
niti staples
8
staple straight
8
straight bridge
8
bridge
7
stress
7
staples
6
computational modeling
4
modeling nickel-titanium
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!