Electrogustometry: validation of bipolar electrode stimulation.

Chem Senses

Smell and Taste Center, Department of Otorhinolaryngology: Head and Neck Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States.

Published: January 2023

Electrogustometry (EGM) is a practical way to test taste. It is typically performed using unipolar electrodes, with the anode on the tongue and the cathode on the hand, forearm, or neck. This results in electric current passing through nontaste tissues and adds a level of impracticality to its clinical application. We compared, using a repeated measures counterbalanced design, anodal thresholds from a unipolar electrode to those of a unique bipolar electrode in which the anode and cathode are contiguously located. Both sides of the anterior tongue were assessed in 70 subjects, as were the effects of age and sex. Nonparametric analyses were performed. The median threshold of the bipolar electrode's central disk (2.49 µA) did not differ from that of the unipolar electrode (2.96 µA) (P = 0.84). On average, older persons exhibited higher thresholds. No significant sex or tongue side effects were evident. Interestingly, when the annular (donut-shaped) bipolar electrode served as the anode, the threshold was higher than that of the other electrodes (5.19 µA; Ps < 0.001). This conceivably reflected lessened summation of activity among adjacent afferents and partial sampling of tongue regions with fewer taste buds. Correlations among all EGM thresholds were nominally higher for women than for men, ranging from 0.83 to 0.85 for women and 0.54 to 0.67 for men; all Ps < 0.001. This study validates the use of a bipolar electrode for assessing taste function, averting movement of current through nontaste-related tissues and making such testing safer and more practical.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chemse/bjad009DOI Listing

Publication Analysis

Top Keywords

bipolar electrode
16
unipolar electrode
8
electrode
6
bipolar
5
electrogustometry validation
4
validation bipolar
4
electrode stimulation
4
stimulation electrogustometry
4
electrogustometry egm
4
egm practical
4

Similar Publications

Purpose: Pulsed electrical field (PEF) ablation is an energy-based technique used to treat a range of cancers by irreversible electroporation (IRE). Our objective was to use computational and plant-based models to characterize the electric field distribution and ablation zones induced with a commercial 8-needle array-based applicator intended for treatment of skin cancer when high-frequency IRE (H-FIRE) pulses are applied. Electric field characterisation of this device was not previously assessed.

View Article and Find Full Text PDF

Purpose: Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlear neural differences.

Methods: Nineteen experienced cochlear implant recipients (9 males and 10 females) were recruited for this study.

View Article and Find Full Text PDF

Anastomotic leakage (AL) is one of the most devastating complications after colorectal surgery. The verification of the adequate perfusion of the anastomosis is essential to ensuring anastomosis integrity following colonic resections. This study aimed to evaluate the efficacy of measuring the electrical activity of the colonic muscularis externa at an anastomosis site for perfusion analysis following colorectal surgery.

View Article and Find Full Text PDF

Novel Dual-Potential Color-Resolved Luminophore Ru(bpy)-Doped CdSe QDs for Bipolar Electrode Electrochemiluminescence Biosensing.

Anal Chem

December 2024

Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China.

The classical electrochemiluminescence (ECL) reagent Ru(bpy) was first doped into CdSe QDs to prepare novel dual-potential color-resolved luminophore Ru-CdSe QDs. Ru-CdSe QDs emitted a strong red ECL signal at a positive potential with coreactant TPrA and a strong green ECL signal at a negative potential with coreactant KSO. As a proof-of-concept application, this work introduced Ru-CdSe QDs into a dual-channel closed bipolar electrode (CBPE) system to construct an ECL biosensor for simultaneous detection of chloramphenicol (CAP) and kanamycin (KAN).

View Article and Find Full Text PDF

Background: Stroke is the leading cause of acquired motor deficiencies in adults. Restoring prehension abilities is challenging for individuals who have not recovered active hand opening capacities after their rehabilitation. Self-triggered functional electrical stimulation applied to finger extensor muscles to restore grasping abilities in daily life is called grasp neuroprosthesis (GNP) and remains poorly accessible to the post-stroke population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!