Background: The temporary cement remaining inside the dental prosthesis can act as a source of microbial colonization and contamination and decrease the final cement retention. Consequently, complete removal of temporary cement before permanent cementation is suggested. This study aimed to assess the effect of different cleaning methods for removing temporary cement on the tensile bond force (TBF) of permanently cemented implant-supported zirconia copings.

Materials And Methods: In this study fifty titanium abutments were screwed onto 50 analogs with 30 Ncm torque into in acrylic resin blocks. Each abutment was scanned separately, and 50 zirconia copings were designed and milled. Permanent resin cement was used to cement copings of control group ( = 10). Copings were divided into two temporary cementation types that in each group, two cleansing methods were used: Temp-S (temporary cement with eugenol and sandblasted after debonding), Samples of the control group were placed in the universal testing machine, and the TBF values were recorded. Samples of the test groups after debonding and cleaning the abutments were subjected to cement with permanent resin cement, aging, and removing. Levene test, two-way analysis of variance (ANOVA), and Tamhane post hoc tests were applied. α = 0.05.

Results: The highest and lowest TBF values were found for the TempNE-SU (554.7 ± 31.5 N) and Temp-S (492.2 ± 48 N) groups, respectively. The two groups of isopropyl alcohol baths in ultrasonics in combination with sandblasting showed statistically higher TBF values than the other two groups that used only sandblasting ( < 0.001) and had similar values compared to the control group.

Conclusion: Sandblasting combined with immersion in an ultrasonic bath containing isopropyl alcohol resulted in statistically similar values to the values of cementation with resin cement from the beginning. However, cleaning the inside of the copings only by sandblasting method reduced the values of the final retention force in comparison to cement with permanent resin cement from the beginning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10028587PMC
http://dx.doi.org/10.4103/1735-3327.369624DOI Listing

Publication Analysis

Top Keywords

temporary cement
20
resin cement
16
cement
13
cement permanent
12
permanent resin
12
tbf values
12
cement eugenol
8
implant-supported zirconia
8
zirconia copings
8
control group
8

Similar Publications

Background: The placement of Temporary Anchorage Devices (TADs) in the mandibular buccal shelf area is a common option for distalizing the lower arch. Therefore, the study of bone thickness and depth in this area is mandatory before planning TAD insertion. The aim of this study was to quantify the width and depth of the mandibular buccal shelf structure and examine its associations with sex, age, skeletal class and vertical pattern.

View Article and Find Full Text PDF

This case report presents a three-year follow-up of a young male with bilateral hindfoot fractures due to a high-energy road traffic accident, resulting in a comminuted open calcaneal fracture on the left and an open fracture-dislocation of the right talus. Staged reconstruction was performed, including initial debridement, temporary cement spacers, and subsequent fixation with femoral head allografts (FHAs). The right foot underwent a tibiotalocalcaneal (TTC) fusion, and the left foot received a double arthrodesis.

View Article and Find Full Text PDF

Assessing correlation between different temporary restorative materials for microleakage following endodontic treatment: an in-vitro study.

BMC Oral Health

December 2024

Department of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 600077, Tamil Nadu, India.

Background: Coronal microleakage, the passage of fluids and bacteria through the interface between the temporary restoration and the tooth structure, can potentially result in endodontic treatment failure.

Purpose: This study evaluated and compared the sealing efficacy of various temporary restorative materials utilized during endodontic procedures.

Methods: All seventy premolar teeth were extracted, measured, and restored, except for the negative control group, where the teeth were left whole.

View Article and Find Full Text PDF

Surface characteristics of resin composite cores and bond strength to CAD/CAM resin matrix glass-ceramic restorations after different treatment protocols.

Odontology

December 2024

Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlandia, Av. Pará, 1720, Bloco 4L, Anexo A, sala 4LA-42, Campus Umuarama, Uberlândia, Minas Gerais, 38405-320, Brazil.

The purpose of this study was to evaluate the impact of various mechanical surface treatments on the surface roughness and microtensile bond strength (µTBS) of aged composite resin cores bonded to CAD/CAM restorations. Composite resin specimens (Filtek Z350 XT, 3M-ESPE/Solventum) were thermally aged and subsequently divided into four groups (n = 36) according to surface treatments: UI-cleaning with ultrasonic diamond tip; AO-sandblasting with 50 µm AlO; DB-cleaning with diamond burs; and CG-positive control group, without aging or surface treatment. Surface roughness was assessed using a profilometer and interferometer, with measurements taken on both sides of each specimen (n = 12).

View Article and Find Full Text PDF

Objective: This study evaluated the effects of finish-line design, tooth preparation taper or total occlusal convergence (TOC), and digital production technology on the retention of provisional crowns for molars.

Material And Methods:  Different taper angles (10° TOC and 20° TOC) and finish line designs (chamfer and shoulder) were used to prepare four mandibular first molar teeth. Two subgroups of the prepared teeth received temporary crowns that were either "Computer-Aided Design" and "Computer-Aided Manufacturing (CAD/CAM) milled or 3D printed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!