Background: A new "terrible triad" has been reported to be an anterior cruciate ligament (ACL) tear with a concomitant medial meniscus ramp tear and lateral meniscus root tear. Patient-reported outcomes (PROs) for isolated ACL reconstruction (ACLR) versus an ACLR with concomitant medial meniscus ramp and lateral meniscus root repairs are not well known.
Purpose: To compare postoperative outcomes between isolated ACLR and ACLR with concomitant medial meniscus ramp and lateral meniscus root repairs.
J Sports Sci
December 2024
Department of Biomechanics, Performance Analysis and Strength & Conditioning, Olympic Training & Testing Centre Westphalia, Dortmund, Germany.
The difficulties of rehabilitation after anterior cruciate ligament (ACL) injuries, subsequent return-to-sport (RTS) let alone achieving pre-injury performance, are well known. Isokinetic testing is often used to assess strength capacities during that process. The aim of the present machine learning (ML) approach was to examine which isokinetic data differentiates athletes post ACL reconstruction (ACLR) and healthy controls.
View Article and Find Full Text PDFAnn Biomed Eng
December 2024
Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Stockholm, Sweden.
Vacuum-assisted delivery (VAD) uses a vacuum cup on the fetal scalp to apply traction during uterine contractions, assisting complicated vaginal deliveries. Despite its widespread use, VAD presents a higher risk of neonatal morbidity compared to natural vaginal delivery and biomechanical evidence for safe VAD traction forces is still limited. The aim of this study is to develop and assess the feasibility of an experimental VAD testing setup, and investigate the impact of traction forces on fetal brain deformation.
View Article and Find Full Text PDFJ Neuroeng Rehabil
December 2024
Section of Physiology, Laboratory of Neuro-Biomechanics, Department of Biomedical and Biotechnological Sciences, School of Medicine, University of Catania, 95123, Catania, Italy.
Background: Autism Spectrum Disorder (ASD) is a neurodevelopmental disorder, characterized by impairments in social interaction and communication with restricted and repetitive behavior. Postural and motor disturbances occur more often in ASD, in comparison to typically developing subjects, affecting the quality of life. Linear and non-linear indexes derived from the trajectory of the center of pressure (COP) while subjects stand on force platforms are commonly used to assess postural stability.
View Article and Find Full Text PDFActa Biomater
December 2024
UCD Centre for Biomedical Engineering, University College Dublin, Belfield, Dublin 4, Ireland; School of Mechanical & Materials Engineering, University College Dublin, Belfield, Dublin 4, Ireland; UCD Charles Institute of Dermatology, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland; The Conway Institute of Biomolecular and Biomedical Research, University College Dublin, Dublin, Ireland. Electronic address:
Microneedle patches (MNs) hold enormous potential to facilitate the minimally-invasive delivery of drugs and vaccines transdermally. However, the micro-mechanics of skin deformation significantly influence the permeation of therapeutics through the skin. Previous studies often fail to appreciate the complexities in microneedle-skin mechanical interactions.