The lifetime of implantable electrochemical glucose monitoring devices is limited due to the foreign body response and detrimental effects from ascorbic acid (AA) and uric acid (UA) interferents that are components of physiological media. Polymer coatings can be used to shield biosensors from these interferences and prolong their functional lifetime. This work explored several approaches to protect redox polymer-based glucose biosensors against such interferences by designing six targeted multi-layer sensor architectures. Biological interferents, like cells and proteins, and UA and AA interferents were found to have individual effects on the current density and operational stability of glucose biosensors, requiring individual protection and treatment. Protection against biofouling can be achieved using a poly(2-methacryloyloxyethyl phosphorylcholine--glycidyl methacrylate) (MPC) zwitterionic polymer coating. An enzyme-scavenging approach was compared to electrostatic repulsion by negatively charged polymers for protection against AA and UA interferences. A multi-layer novel polymer design (PD) system consisting of a cross-linkable negatively charged polyvinylimidazole-polysulfostyrene co-polymer inner layer and a cross-linkable MPC zwitterionic polymer outer layer showed the best protection against AA, UA, and biological interferences. The sensor protected using the novel PD shield displayed the lowest mean absolute relative difference between the glucose reading without the interferent and the reading value with the interferent present and also displayed the lowest variability in sensor readings in complex media. For sensor measurements in artificial plasma, the novel PD extends the linear range ( = 0.99) of the sensor from 0-10 mM for the control to 0-20 mM, shows a smaller decrease in sensitivity, and retains high current densities. The application of PD multi-target coating improves sensor performance in complex media and shows promise for use in sensors operating in real conditions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10152486 | PMC |
http://dx.doi.org/10.1021/acssensors.3c00050 | DOI Listing |
ACS Omega
January 2025
Department of Physics, Faculty of Science, Kasetsart University, Bangkok 10900, Thailand.
Nickel-based metal-organic frameworks, denoted as three-dimensional nickel trimesic acid frameworks (3D Ni-TMAF), are gaining significant attention for their application in nonenzymatic glucose sensing due to their unique properties. Ni-MOFs possess a high surface area, tunable pore structures, and excellent electrochemical activity, which makes them ideal for facilitating electron transfer and enhancing the catalytic oxidation of glucose. This research describes a new electrochemical enzyme-mimic glucose biosensor in biological solutions that utilizes 3D nanospheres Ni-TMAF created layer-by-layer on a highly porous nickel substrate.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
School of Light Industry and Chemical Engineering, Dalian Polytechnic University, Dalian 116034, China. Electronic address:
Accurate, specific, and cost-effective detection of toxic cyanogenic glycosides is crucial for ensuring biological health and food safety. In this study, a novel biosensor based on co-immobilized multi-enzyme system was constructed by artificial antibody-antigen-directed immobilization for the colorimetric detection of amygdalin through a cascade reaction catalyzed by β-glucosidase, glucose oxidase, and horseradish peroxidase. Artificial antibodies and antigens were prepared using catechol and 3,4-dihydroxybenzaldehyde, respectively, to generate mutual affinity recognition ability for enzyme immobilization.
View Article and Find Full Text PDFTalanta
January 2025
Key Laboratory for Physical Electronics and Devices of the Ministry of Education & School of Science & Shaanxi Key Laboratory of Information Photonic Technique & Institute of Wide Bandgap Semiconductors, Xi'an Jiaotong University, Xi'an, 710049, China. Electronic address:
Glucose detection is crucial for diagnosis, prevention and treatment of diabetes mellitus. In this work, 10 nm AlO thin film was introduced on the channel of diamond solution-gate field-effect transistor (SGFET) to improve the performance of glucose detection. AFM results show the roughness of channel surface increased after AlO thin film deposition.
View Article and Find Full Text PDFCurr Pharm Des
January 2025
Shandong Provincial Key Medical and Health Laboratory of Hydrogen Biomedical Research & Key Laboratory of Major Diseases and Hydrogen Medical Translational Applications in Universities of Shandong Province, Taishan Institute for Hydrogen Biomedical Research, The Second Affiliated Hospital of Shandong First Medical University, Tai'an, China.
Molecular hydrogen (H2) is considered a biological antioxidant. Hydrogen-rich Water (HRW) is regular water that contains dissolved H2 and has become more widely used in recent years. This review summarizes the basic research and clinical applications of HRW consumption to support its use for daily health and clinical treatment.
View Article and Find Full Text PDFMikrochim Acta
January 2025
College of Medical Technology, Chengdu University of Traditional Chinese Medicine, Chengdu, 611137, China.
An innovative colorimetric sensing strategy was developed for the detection of glucose by the integration of glucose aptamer, glucose oxidase (GOx), and horseradish peroxidase (HRP), termed aptamer proximal enzyme cascade reactions (APECR). In the presence of glucose, aptamer binding enables GOx to catalyze glucose oxidation into HO efficiently. Subsequently, the adjacent HRP catalyzes the oxidation of the peroxidase substrate, 2,2'-biazobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), utilizing the generated HO, resulting in a distinct color change.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!