Background: Total abnormal pulmonary venous return anomaly is a CHD characterised by abnormal pulmonary venous flow directed to the right atrium. In this study, we aimed to compare the effects of these techniques on early rhythm problems in total abnormal pulmonary venous return anomaly cases operated with conventional or primary sutureless techniques.

Method: Seventy consecutive cases (median age 1 month, median weight 4 kg) who underwent total abnormal pulmonary venous return anomaly repair with conventional or primary sutureless technique between May 1 2020 and May 1 2022 were evaluated. The rate, diagnosis, and possible risk factors of postoperative arrhythmias were investigated. The results were evaluated statistically.

Results: When the total abnormal pulmonary venous return anomaly subgroup of 70 cases was evaluated, 40 cases were supracardiac, 18 cases were infracardiac, 7 cases were cardiac, and 5 cases were mixed type. Twenty-eight (40%) cases had a pulmonary venous obstruction. Primary sutureless technique (57%, supracardiac n = 24, mixed = 3, infracardiac = 13) was used in 40 patients. Median cardiopulmonary bypass time (110 versus 95 minutes) and median aortic clamp time (70 versus 60 minutes), median peak lactate (4.7 versus 4.8 mmol/l) in the first 72 hours, and median peak vasoactive inotropic score in the first 72 hours of the primary sutureless and conventional technique used cases value (8 versus 10) were similar. The total incidence of arrhythmias in the conventional group was significantly higher than in the primary sutureless group (46.7% versus 22.5%, p = 0.04). Supraventricular early beat was observed in 3 (7.5%), sinus tachycardia was seen in 6 (15%), junctional ectopic tachycardia was seen in 1 (2.5%), intra-atrial reentry tachycardia was seen in 1 (2.5%), usual supraventricular tachyarrhythmia was seen in 2 cases (5%) in the primary sutureless group. In the conventional group, supraventricular early beat was observed in six of the cases (20%), sinus tachycardia in five (16.7%), junctional ectopic tachycardia in four (13.3%), intra-atrial reentry tachycardia (10%) in three, and supraventricular tachyarrhythmia in seven cases (23.3%). In the first 30 days, there was a similar mortality rate (10% versus 10%), with four patients in the primary sutureless group and three in the conventional group. The median follow-up period of the cases was 8 months (interquartile range (IQR) 6-10 months). In the follow-up, arrhythmias were detected in two cases (one supraventricular tachyarrhythmia and one intra-atrial reentry tachycardia) in the primary sutureless group and three cases (two supraventricular tachyarrhythmia, one intra-atrial reentry tachycardia) in the conventional technique. All cases were converted to normal sinus rhythm with cardioversion and combined antiarrhythmic therapy.

Conclusion: Different arrhythmias can be observed in the early period in patients with operated total abnormal pulmonary venous return anomaly. Although a higher rate of rhythm problems was observed in the early period in the conventional method compared to the primary sutureless technique, no significant effect was found on mortality and morbidity between the groups.

Download full-text PDF

Source
http://dx.doi.org/10.1017/S1047951123000513DOI Listing

Publication Analysis

Top Keywords

primary sutureless
40
pulmonary venous
32
abnormal pulmonary
28
total abnormal
24
venous return
24
return anomaly
24
cases
16
sutureless group
16
intra-atrial reentry
16
reentry tachycardia
16

Similar Publications

We report three cases demonstrating the efficacy and versatility of the micro-incision scleral tunnel (MIST) technique, a novel method for Ahmed glaucoma valve (AGV) tube insertion. MIST is characterized by its small incision, sutureless approach, anterior-to-posterior tunnel creation, and allograft-free design. The technique involves creating a scleral tunnel using a 1-mm crescent knife (Bleb Knife II), allowing for secure tube placement into the anterior chamber, ciliary sulcus, or vitreous cavity.

View Article and Find Full Text PDF

Robustly Injectable Tetra-PEG Hydrogel Sealants for Annulus Fibrosus Repair.

Adv Healthc Mater

November 2024

Department of Orthopaedic, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, 1111 Xianxia Road, Shanghai, 200336, China.

Discectomy serves as the primary therapeutic approach for lumbar disc herniation, but the annular fibrosus defects after discectomy may lead to recurrence of disc herniation. Despite recent advances in bioinspired adhesives to seal the AF defect, the growing popularity of endoscopic discectomy has put forward high requirements for the tissue bioadhesives with rapid injectability, easy operation, and robust tissue adhesion in underwater environments. Herein, a rapidly in situ forming injectable tetra-PEG bioadhesive (ISG) comprising of FDA-approved tetra-armed poly (ethylene glycol) amine (tetra-PEG-NH) and tetra-armed poly (ethylene glycol) succinimidyl glutarate (tetra-PEG-SG) for the sutureless closure of AF defects, is reported.

View Article and Find Full Text PDF

Assessment of transfer-time and time-to-surgery as risk factors to survival in Gastroschisis (GS) in a LMIC; an eight-year review.

Pediatr Surg Int

November 2024

Department of Paediatric Surgery, Kasr AlAiny Faculty of Medicine, Cairo University Specialized Paediatric Hospital, Cairo University, Ali Ibrahim Street, Mounira, Cairo, 11241, Egypt.

Background: The management of Gastroschisis in LMICs continues to be a challenge and is associated with very poor outcomes in contrast with HICs where survival rates near 100%. The purpose of this work is to provide an overview of survival over the past 8 years in a high-flow tertiary centre in Africa. It also investigates the effect of transfer-time and time-to-surgery on outcome.

View Article and Find Full Text PDF

Background Inguinal hernia repair is a common surgical procedure addressing the protrusion of abdominal viscera through the inguinal canal. Despite advancements, complications such as chronic postoperative pain, infections, and hernia recurrence persist. Traditional sutured polypropylene mesh can cause nerve irritation and inflammation, leading to chronic pain and other issues.

View Article and Find Full Text PDF

The surgical outcome of sutureless skin closures using Octyl-2-cyanoacrylate (Dermabond™) versus Steri-Strip™.

Natl J Maxillofac Surg

July 2024

Oral Medicine and Radiology, Faculty of Dental Sciences, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India.

Introduction: Cosmesis is the primary concern for the patient undergoing facial surgery and there are numbers of well proven materials that are available such as adhesive tapes, subcuticular suture, skin adhesive or glue to achieve better cosmesis. The objective of our study was to assess the surgical outcome of sutureless skin closures using Octyl-2-cyanoacrylate (Dermabond™) versus Steri-Strip™.

Method: The present prospective study was conducted in 20 patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!