Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
To control the spread and transmission of airborne particles (especially SARS-CoV-2 coronavirus, recently) in the indoor environment, many control strategies have been employed. Comparisons of these strategies enable a reasonable choice for indoor environment control and cost-effectiveness. In this study, a series of experiments were conducted in a full-scale chamber to simulate a conference room. The control effects of four different strategies (a ventilation system (320 m/h) with and without a baffle, a specific type of portable air cleaner (400 m/h) and a specific type of desk air cleaner (DAC, 160 m/h)) on the transportation of particles of different sizes were studied. In addition, the effects of coupling the ventilation strategies with five forms of indoor airflow organization (side supply and side or ceiling return, ceiling supply and ceiling or side return, floor supply and ceiling return) were evaluated. The cumulative exposure level (CEL) and infection probability were selected as evaluation indexes. The experimental results showed that among the four strategies, the best particle control effect was achieved by the PAC. The reduction in CEL for particles in the overall size range was 22.1% under the ventilation system without a baffle, 34.3% under the ventilation system with a baffle, 46.4% with the PAC, and 10.1% with the DAC. The average infection probabilities under the four control strategies were 11.3-11.8%, 11.1-11.8%, 9.1-9.5%, and 18.2-19.7%, respectively. Among the five different forms of airflow organization, the floor supply and ceiling return mode exhibited the best potential ability to remove particles.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9996463 | PMC |
http://dx.doi.org/10.1016/j.apr.2023.101716 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!