A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Delayed Tracheoesophageal Fistula and Refractory Respiratory Failure Caused by Inhalation Burns and Emergency Venovenous ECMO to Facilitate Its Management: A Case Report. | LitMetric

Acquired tracheoesophageal fistulae are uncommon in burn patients but can occur as a complication of inhalation injury. We report a case of a 30-yr-old male patient presenting after suffering from inhalation and 25% total body surface area burns. On postburns day 14, he developed a massive tracheoesophageal fistula causing refractory acute respiratory failure. Veno-venous extracorporeal membrane (VV ECMO) oxygenation was initiated without systemic anticoagulation via bi-femoral cannulation under transthoracic echocardiography guidance. He underwent successful 5-hr apnoeic ventilation-assisted surgical repair of the fistula via a right posterolateral thoracotomy. ECMO was discontinued after 36 hr, and he was discharged to the ward after 33 d in the intensive care unit. Inhalation burn injury can cause a delayed life-threatening tracheoesophageal fistula. Surgical repair can be successfully performed for this condition. VV- ECMO can be used to facilitate prolonged apnoeic surgery and to manage refractory respiratory failure due to this condition.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jbcr/irad040DOI Listing

Publication Analysis

Top Keywords

tracheoesophageal fistula
12
respiratory failure
12
refractory respiratory
8
ecmo facilitate
8
surgical repair
8
delayed tracheoesophageal
4
fistula
4
fistula refractory
4
failure caused
4
inhalation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!