Background: A new generation of enhanced monofocal IOLs has been introduced to slightly increase the depth of focus as compared to standard monofocal IOLs. The purpose of this study is to evaluate the effect of pupil size on the through-focus optical performance of three new enhanced monofocal IOLs, designed to improve the range of vision as compared to standard monofocal IOLs.
Methods: Optical bench testing in white light was performed for different pupils, using an average cornea eye. Distance image quality was evaluated using Modulation Transfer Function (MTF) measurements. Through-focus Visual Acuity (VA) was simulated from these measurements (sVA). Three enhanced monofocal IOLs (ICB00, ISOPure, and RayOne-EMV) and three standard monofocal IOLs: two aspheric (ZCB00 and SN60WF) and one spherical (AAB00) were included.
Results: The enhanced monofocal IOLs provided an improvement in the intermediate sVA as compared to standard monofocal IOLs. For ICB00, the improvement was independent of the pupil size, while for the ISOPure and RayOne-EMV, the intermediate sVA improved with increased pupil size. Similar to the spherical monofocal IOL, the ISOPure and RayOne-EMV showed a strong correlation between improvement in intermediate sVA and reduction of distance sVA and MTF, and increasing pupil size. ICB00 provided the same distance sVA as the aspheric monofocal IOLs and the lowest variability in MTF with pupil size.
Conclusion: Optical bench results showed that the ISOPure and RayOne-EMV provide similar performance to a spherical monofocal IOL, with a strong pupil dependency for distance and intermediate vision. The other enhanced monofocal IOL, ICB00, provided a sustained improvement in simulated intermediate VA and maintained distance image quality comparable to that of the standard aspheric monofocal IOLs, even for larger pupils.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10026412 | PMC |
http://dx.doi.org/10.1186/s12886-023-02839-y | DOI Listing |
Life (Basel)
January 2025
Centro Oftalmológico Charles, Buenos Aiers C1116, Argentina.
Background: The aim of this study was to evaluate visual outcomes and patient satisfaction after bilateral implantation of a new hydrophobic acrylic intraocular lens called Clareon (Alcon) using the mini-monovision technique.
Methods: A single-center, prospective, nonrandomized study was conducted in Tandil (Buenos Aires, Argentina), including patients scheduled for cataract surgery. To achieve mini-monovision, the spherical equivalent was calculated between -0.
J Cataract Refract Surg
January 2025
Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK.
Purpose: To measure visual acuity at three different defocus planes in pseudophakic subjects with varying levels of spherical aberration induced by an adaptive optics visual simulator. The study aimed to simulate Extended Depth of Focus (EDOF) intraocular lenses (IOLs).
Setting: Private hospital (IMO, Barcelona, Spain).
Biomed Opt Express
January 2025
Center for Visual Science, The Institute of Optics, Flaum Eye Institute. University of Rochester, Rochester, NY, USA.
An intraocular lens (IOL) replaces the natural crystalline lens during cataract surgery, and although the vast majority of implants have simple optics, "advanced technology" IOLs have multifocal and extended depth of focus (EDOF) properties. Optical concepts are evaluated here, with image contrast, focal range, and unwanted visual phenomena being the primary concerns. Visual phenomena with earlier bifocal diffractive lenses led to alternative diffractive designs (trifocals, etc.
View Article and Find Full Text PDFKlin Monbl Augenheilkd
January 2025
Department of Ophthalmology, Pallas Kliniken, Olten/Bern/Zürich/Dübendorf, Switzerland.
Background: Extended monovision is a novel mix-and-match approach that has been recently introduced. It involves implanting an aspherical monofocal intraocular lens (IOL) for distance vision in the dominant eye, and a bifocal extended depth-of-focus (EDOF) IOL in the nondominant eye. The target refraction for the nondominant eye is - 1.
View Article and Find Full Text PDFJ Ophthalmol
December 2024
Department of Optics & Optometry & Vision Sciences, University of Valencia, Valencia, Spain.
This study aims to analyze the prevalence and severity of posterior capsule opacification (PCO) and glistening in a new hydrophobic biaspheric monofocal intraocular lens (IOLs) 24 months after implantation. By means of a ambispective, observational, case-control design, a total of 297 eyes from 200 cataract surgery patients were included in the study (118 females and 82 males; mean age: 72.31 ± 9.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!