A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Toolkit for Monitoring Immunoglobulin G Levels from Dried Blood Spots of Patients with Primary Immunodeficiencies. | LitMetric

Purpose: This study assessed whether measuring immunoglobulin G (IgG) from dried blood spots (DBSs) using nephelometry is a suitable remote monitoring method for patients with primary immunodeficiencies (PID).

Methods: Patients receiving immunoglobulin replacement therapy for PID were included in this non-interventional single-arm study (DRKS-ID: DRKS00020522) conducted in Germany from December 4, 2019, to December 22, 2020. Three blood samples, two capillary DBSs (one mail-transferred and the other direct-transferred to the laboratory), and one intravenous were collected from each patient. IgG levels were determined using nephelometry. IgG levels were summarized descriptively, and significant differences were assessed using Wilcoxon matched-pairs signed-rank tests. Correlation and agreement between IgG levels were assessed using Spearman correlation and Bland-Altman analyses, respectively.

Results: Among 135 included patients, IgG levels measured from DBS samples were lower than those measured in serum (p < 0.0001). There was no significant difference between IgG levels in direct- and mail-transferred DBS samples. There was a high degree of correlation between IgG levels in serum samples and DBS samples (r = 0.94-0.95). Although there was a bias for higher levels of IgG in serum than in DBS samples, most samples were within the 95% interval of agreement. There was a high degree of correlation between IgG levels measured in direct- and mail-transferred DBS samples (r = 0.96) with no bias based on the shipment process and most samples within the 95% interval of agreement.

Conclusion: Monitoring IgG levels from DBS samples is a suitable alternative to the standard method, and results are not substantially affected by mailing DBS cards.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10027597PMC
http://dx.doi.org/10.1007/s10875-023-01464-0DOI Listing

Publication Analysis

Top Keywords

igg levels
16
dried blood
8
blood spots
8
patients primary
8
primary immunodeficiencies
8
levels
5
igg
5
toolkit monitoring
4
monitoring immunoglobulin
4
immunoglobulin levels
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!