Coronary stent failure: role of a blended approach with drug-coated balloons for complex lesions.

Minerva Cardiol Angiol

Fondazione Ricerca e Innovazione Cardiovascolare, Milan, Italy.

Published: June 2024

The management of coronary artery disease by means of percutaneous approach have been focused initially to overcome the recoil and acute occlusion after vessel ballooning; therefore, to develop and improve metallic stent platforms, and later drug-eluting technologies. Contemporarily, the necessity emerged to optimize interventional procedures using functional physiologic tests and intravascular imaging guidance, but still stent failures, especially in the complex lesion setting, continue to be not negligible. This comprehensive review is focused on the technology of drug-coated balloons as a tool to treat coronary artery disease without the need for metal implantation but still eluting antirestenotic drugs such as paclitaxel or sirolimus. We delve into these technologies, the drugs, the technical aspects of the deployment and the most updated evidence also proposing a dedicated interventional algorithm. There is solid data to support the use of drug-coated balloons in patients with in-stent restenosis and de-novo small coronary artery disease but also new evidence with promising results from recent studies indicate the feasibility of this approach in complex coronary interventions, bifurcation lesions and larger coronary vessels. In this state-of-the-art review, we also propose a blended approach based on the combination of drug-eluting stents and drug-coated balloons, keeping in mind the necessity to reduce the total stent length in order to reduce the long-term risk of complications.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S2724-5683.22.06172-5DOI Listing

Publication Analysis

Top Keywords

drug-coated balloons
16
coronary artery
12
artery disease
12
blended approach
8
coronary
6
coronary stent
4
stent failure
4
failure role
4
role blended
4
approach
4

Similar Publications

Background: Few studies investigated the implications of post-PCI QFR and post-PCI ΔQFR (absolute increase of QFR) in de novo lesions of small coronary disease after drug-coated balloon (DCB).

Objectives: We sought to investigate the prognostic implications of post-PCI QFR and post-PCI ΔQFR in patients who received DCB only.

Methods: Patients were divided according to the optimal cutoff value of the post-PCI QFR and the post-PCI ΔQFR.

View Article and Find Full Text PDF

Vessel Wall Histologic Changes in a Porcine Model of Arteriovenous Fistula Stenosis Treated with Percutaneous Transluminal Angioplasty.

J Vasc Interv Radiol

December 2024

Vascular and Interventional Radiology Translational Research Lab, Mayo Clinic, Rochester, MN, USA; Department of Radiology, Mayo Clinic, Rochester, MN, USA. Electronic address:

Article Synopsis
  • The study investigated how different treatments (balloon angioplasty vs. drug-coated balloons) affect the changes in blood vessel tissues following arteriovenous fistula stenosis in pigs with chronic kidney disease.
  • Significant differences in tissue composition were observed, with drug-coated balloons leading to lower neointimal growth and higher endothelial cell counts compared to standard angioplasty.
  • The findings suggest that using drug-coated balloons may improve vessel healing and reduce complications over time, as shown by varied immune cell responses and tissue growth patterns.
View Article and Find Full Text PDF

Introduction: Initial surgical revascularization has a recognized primary role in patients with critical limb-threatening ischemia with a high-quality great saphenous vein for conduit. However, approximately one-third of lower extremity vein grafts develop lesions threatening graft patency. Traditional treatments have limitations, highlighting the need for innovative solutions.

View Article and Find Full Text PDF

Background: The impact of below-the-knee (BK) runoff after drug-coated balloon (DCB) treatment in femoropopliteal (FP) lesions has not been well investigated.

Methods: This retrospective multicenter observational study enrolled 291 consecutive patients with lower extremity artery disease who underwent endovascular therapy with DCBs for FP lesions between January 2018 and December 2021. Patients were classified into four groups based on the BK runoff.

View Article and Find Full Text PDF

Background: Drug-coated balloons (DCB) are emerging as an alternative to permanent implants for managing de novo coronary artery disease, particularly in small vessels (SVD). This sub-analysis of the PICCOLETO II study aimed to compare the performance of DCB and DES in terms of Murray's law-based quantitative flow ratio (μFR) changes between baseline, post-percutaneous coronary intervention (PCI), and follow-up.

Methods: Patients with a clinical indication for PCI were assigned to receive either Xience DES or Elutax SV/Emperor DCB.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!