Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The DNA biosensors are powerful tools in the gene mutation or pathogens detection. That is why there are a lot of DNA detection strategies and methods. Here we present the insight on a slightly overlooked DNA detection technique, surface-enhanced Raman scattering (SERS). The present work is a summary of the influence of the plasmonic metal of the SERS substrate and strategy of the sandwich-type biosensor construction, simply the placement of the Raman reporter and mismatches, on the SERS signal enhancement. We found that, although in general there is an increase in the intensity of the SERS signal when the distance between the Raman scatterer and the SERS-active surface decreases, for this type of DNA SERS sensor a greater intensity of the measured Raman signal is usually observed when the Raman reporter is farther away from the plasmonic substrate. This is probably caused by a significant change in the hybridisation efficiency for the different structures of the sensor analysed due to some steric hindrances.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.saa.2023.122606 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!