Objective: To determine the difference in the marginal accuracy at buccal, lingual, mesial and distal margins of temporary crowns fabricated with bisacryl-based temporary crown material.

Methods: The in-vitro, experimental, laboratory-based study was conducted at the Aga Khan University, Karachi, from September to December 2019, and comprised two bisacryl-based temporary crown material, Integrity and Protemp 4, which were used to fabricate a sample of 24 temporary crowns. A pre-operative polyvinyl siloxane impression served as a template for temporary crown fabrication. A right mandibular molar tooth on a typodont was prepared to receive a crown. The provisional crown material was syringed onto the template and was allowed to cure. All four surfaces of the crown were observed under a stereomicroscope equipped with digital single-lens reflex camera at 25.6x magnification. An image of each surface was captured and a photographic record was maintained. An image processing software was used for the measurement of marginal discrepancy. Marginal accuracy among the four surfaces was assessed. Data was analysed using SPSS 23.

Results: Mean marginal discrepancy for provisional crowns fabricated with Protemp 4 and Integrity was 410±222μm and 319±176μm, respectively. The marginal discrepancy between the two groups was statistically significant (p=0.027), with buccal margin exhibiting the most discrepancy (p<0.01).

Conclusions: Integrity showed less microleakage than Protemp 4. Among all the walls, the buccal wall showed the most microleakage. Marginal accuracy was found to be dependent upon the type of provisional crown material and the side of the prepared axial wall.

Download full-text PDF

Source
http://dx.doi.org/10.47391/JPMA.5008DOI Listing

Publication Analysis

Top Keywords

marginal accuracy
12
temporary crown
12
marginal discrepancy
12
provisional crown
8
temporary crowns
8
crowns fabricated
8
bisacryl-based temporary
8
crown material
8
crown
7
marginal
5

Similar Publications

Background: High-resolution brain imaging is crucial in clinical diagnosis and neuroscience, with ultra-high field strength MRI systems ( ) offering significant advantages for imaging neuronal microstructures. However, achieving magnetic field homogeneity is challenging due to engineering faults during the installation of superconducting strip windings and the primary magnet.

Purpose: This study aims to design and optimize active superconducting shim coils for a 7 T animal MRI system, focusing on the impact of safety margin, size, and adjustability of the second-order shim coils on the MRI system's optimization.

View Article and Find Full Text PDF

The impact of three-dimensional (3D) dose delivery accuracy of C-arm linacs on the planning target volume (PTV) margin was evaluated for non-coplanar intracranial stereotactic radiosurgery (SRS). A multi-institutional 3D starshot test using beams from seven directions was conducted at 22 clinics using Varian and Elekta linacs with X-ray CT-based polymer gel dosimeters. Variability in dose delivery accuracy was observed, with the distance between the imaging isocenter and each beam exceeding 1 mm at one institution for Varian and nine institutions for Elekta.

View Article and Find Full Text PDF

Application of a semi-active robotic system for implant placement in atrophic posterior maxilla: a retrospective case series.

J Dent

January 2025

Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University. Electronic address:

Objective: The study aimed to evaluate the accuracy and safety of the semi-active robotic system for implant placement in atrophic posterior maxilla.

Methods: Patients underwent robot-assisted implant placement in atrophic posterior maxilla were identified and included. Cone-beam computed tomography (CBCT) was performed before surgery.

View Article and Find Full Text PDF

Abnormal network homogeneity in patients with bipolar disorder in attention network.

Brain Imaging Behav

January 2025

Key Laboratory of Adolescent Cyberpsychology and Behavior (Ministry of Education), Wuhan, China.

Bipolar disorder (BD) is a complex psychiatric condition marked by significant mood fluctuations that deeply affect quality of life. Understanding the neural mechanisms underlying BD is critical for improving diagnostic accuracy and developing more effective treatments. This study utilized resting-state functional magnetic resonance imaging (rs-fMRI) to investigate functional connectivity within the ventral and dorsal attention networks in 52 patients with BD and 51 healthy controls.

View Article and Find Full Text PDF

Comparison of computed tomographic findings for radiolucent lesions of the mandibular ameloblastoma, odontogenic keratocyst, dentigerous cyst, and simple bone cyst.

J Dent Sci

January 2025

Section of Oral and Maxillofacial Oncology, Division of Maxillofacial Diagnostic and Surgical Sciences, Faculty of Dental Science, Kyushu University, Fukuoka City, Fukuoka, Japan.

Background/purpose: Radiolucent lesions of the mandible, including ameloblastoma, odontogenic keratocyst (OKC), dentigerous cyst (DC) and simple bone cyst (SBC), are frequently encountered in clinical practice. However, they vary in type and occasionally in appearance. Each lesion needs a different treatment and approach; therefore, accurate diagnosis is crucial before treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!