A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Longitudinal Force Measurement and its Relationship to Technical Competence for Esophageal Anastomosis in a Thoracoscopic Esophageal Atresia/Tracheo-Esophageal Fistula Simulator. | LitMetric

Purpose: Thoracoscopic esophageal atresia with tracheo-esophageal fistula (EA/TEF) repair requires the gentle manipulation of delicate tissue. Force sensors were attached to the upper and lower esophagus of a 3D-printed EA/TEF simulator to explore force parameters as markers of performance.

Methods: Participants completed one intracorporeal suture between the anterior walls of upper and lower esophageal ends. Longitudinal force data were recorded at each end. A blinded pediatric surgeon marked attempt videos. Excessive force events, maximum tension, and force interquartile range (IQR) were measured. Data were reported as median (range) significance of p < 0.05.

Results: 17 participants of varying levels of experience performed the task. OSATS scores showed significant differences between experts and novices. Experts completed the task in a median time of 4 min. They used lower maximum tension, higher force IQR, and had fewer excess force events compared to the intermediate and novice groups.

Discussion: The application of force was dependent on expertise with more skilled participants having fewer excess force events. The higher expert force IQR likely reflects the consistent tension needed for task completion. Analysis of force data may be an indicator of competence, and trainees may benefit from a thoracoscopic simulator which provides force data feedback.

Level Of Evidence: Not applicable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpedsurg.2023.02.026DOI Listing

Publication Analysis

Top Keywords

longitudinal force
8
thoracoscopic esophageal
8
upper lower
8
force
5
force measurement
4
measurement relationship
4
relationship technical
4
technical competence
4
esophageal
4
competence esophageal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!