Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Improvements in continuous glucose monitoring (CGM) in recent years have changed the treatment of type 1 diabetes (T1D) by permitting the automation of glucose control. The Minimed 780G advanced hybrid closed-loop (ACHL) system adapts basal infusion rates and delivers auto-correction boluses in order to achieve a user-decided glucose target (100, 110 or 120mg/dL). This study set out to evaluate the effectiveness of the Medtronic 780G system in real-life conditions over 6 months.
Materials And Methods: Prospective study that included T1D subjects previously treated with insulin pump without CGM (pump group) or with sensor-augmented pump with predictive low-glucose suspend (SAP-PLGS group) who started with the Minimed 780G system. Sensor and pump data from baseline, and at 1, 3 and 6 months were downloaded and HbA1c was recorded at baseline and at 6 months.
Results: Fifty T1D subjects were included; 25 were previous SAP-PLGS 640G users and 25 used 640G without CGM. 66% were female, 48.6 (40-57) years of age with 20 (12-31.5) years of diabetes duration. Time in range (TIR) improved in the total cohort from baseline to 6 months (69% (57.7-76) vs. 74% (70-82); p=0.01 as did HbA1c (7.6% (7.1-7.8) vs. 7.0% (6.8-7.5); p<0.001), with improvement in times <54, >180 and >250mg/dL. Outcomes at 6 months did not differ between groups, although the SAP-PLGS subjects were prone to hypoglycaemia and the pump group mainly presented suboptimal metabolic control.
Conclusion: The AHCL Medtronic Minimed 780G system achieves and maintains good glycaemic control over 6 months in real-life conditions in different profiles of T1D subjects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.endien.2022.10.005 | DOI Listing |