A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of fitting methods, high b-values and image quality on diffusion and perfusion quantification and reproducibility in the calf. | LitMetric

Effects of fitting methods, high b-values and image quality on diffusion and perfusion quantification and reproducibility in the calf.

Comput Biol Med

Cardiovascular & Metabolic Disorders Program, Duke-National University of Singapore Medical School, Singapore; National Heart Research Institute Singapore, National Heart Centre, Singapore; Yong Loo Lin School of Medicine, National University Singapore, Singapore; The Hatter Cardiovascular Institute, University College London, London, UK.

Published: May 2023

Purposes: The study aimed to optimize diffusion-weighted imaging (DWI) image acquisition and analysis protocols in calf muscles by investigating the effects of different model-fitting methods, image quality, and use of high b-value and constraints on parameters of interest (POIs). The optimized modeling methods were used to select the optimal combinations of b-values, which will allow shorter acquisition time while achieving the same reliability as that obtained using 16 b-values.

Methods: Test-retest baseline and high-quality DWI images of ten healthy volunteers were acquired on a 3T MR scanner, using 16 b-values, including a high b-value of 1200 s/mm, and structural T1-weighted images for calf muscle delineation. Three and six different fitting methods were used to derive ADC from monoexponential (ME) model and D, f and D from intravoxel incoherent motion (IVIM) model, with or without the high b-value. The optimized ME and IVIM models were then used to determine the optimal combinations of b-values, obtainable with the least number of b-values, using the selection criteria of coefficient of variance (CV) ≤10% for all POIs.

Results: The find minimum multivariate algorithm was more flexible and yielded smaller fitting errors. The 2-steps fitting method, with fixed D, performed the best for IVIM model. The inclusion of high b-value reduced outliers, while constraints improved 2-steps fitting only.

Conclusions: The optimal numbers of b-values for ME and IVIM models were nine and six b-values respectively. Test-retest reliability analyses showed that only ADC and D were reliable for calf diffusion evaluation, with CVs of 7.22% and 4.09%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2023.106746DOI Listing

Publication Analysis

Top Keywords

high b-value
16
fitting methods
8
image quality
8
optimal combinations
8
combinations b-values
8
ivim model
8
ivim models
8
2-steps fitting
8
b-values
6
high
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!