A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of haptoglobin in saliva of cows: Validation of an assay and a pilot study of its potential application. | LitMetric

Measurement of haptoglobin in saliva of cows: Validation of an assay and a pilot study of its potential application.

Res Vet Sci

Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, Regional Campus of International Excellence Campus Mare Nostrum, University of Murcia, 30100 Murcia, Spain. Electronic address:

Published: May 2023

In recent years, the use of saliva as a matrix for the measurement of biomarkers of health and welfare is gaining importance due to its non-invasive collection. Haptoglobin (Hp) is an acute-phase protein involved in the inflammatory response and changes in its concentration can provide information about the health status of the animals. This study aimed to develop and validate an assay based on luminescent amplification (AlphaLISA technology) for the measurement of Hp in bovine saliva and to study the possible changes in different inflammatory situations such as peripartum period and lameness. The assay proved to be accurate, reliable, and sensitive for the measurement of Hp in cow saliva (coefficient of variation (CV) 7.57%; coefficient of determination (R) 0.992; recovery test 105.15%; lower limit of quantification (LLQ) 7.9 ng/ml). Significant differences were observed between Hp levels in saliva of cows before (13 days before) and after (7 and 20 days after) calving and at the moment of calving (p < 0.0001), and between lame and healthy cows (p < 0.008). In conclusion, this assay can detect Hp in a precise, sensitive, and accurate way in saliva of cows. Future studies with a larger population and different disease conditions should be conducted to determine the potential of Hp as an inflammatory biomarker in cow saliva.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rvsc.2023.03.005DOI Listing

Publication Analysis

Top Keywords

saliva cows
8
saliva
5
measurement
4
measurement haptoglobin
4
haptoglobin saliva
4
cows validation
4
validation assay
4
assay pilot
4
pilot study
4
study potential
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!