A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Defining the fit and ideal entry site of the fibula rod system--a computed tomography based study in elderly patients with lower limb infections, vascular diseases or tumors. | LitMetric

Objectives: To determine the configuration of the distal fibula anatomy and the fitness of the Fibula Rod System (Acumed®, Hillsboro, Oregon) in a series of fibula models and to determine the optimal entry site of the rod.

Methods: Consecutive series of computed tomography (CT) of tibias and fibulae with no fracture or deformity were converted to stereo-lithograph format, and imported into Meshmixer software (Autodesk, San Rafael, California). A 3.6 × 180 mm fibula rod model was virtually inserted to best fit the intramedullary canal of the fibula model and to a depth of 0 mm proud at the distal fibula. The location of the entry point in relationship to the fibular tip, and the distance between the rod and the lateral fibula cortex were measured.

Results: CT of 41 fibulae (23 male and 18 female patients) contributed to the three-dimensional fibula modeling. The entry point was 3.5 mm (SD 2.0) medial to (in mortise view) and 1.0 mm (SD 2.1) anterior to (in lateral view) the fibular tip. The fibula rod was inserted to a depth of 6.2 mm (SD 2.1) proximal to the fibula tip. The mean shortest distance of the rod to the outer cortex was 1.88 mm (SD 0.87). There was a breach of the posterolateral cortex in one patient.

Conclusion: The guide pin entry site of fibula rod should be medial and anterior offset with reference to the fibula tip, in contrary to the distal tip as recommended in the manual. There is a chance of breaching the posterolateral cortex with rod entry.

Download full-text PDF

Source
http://dx.doi.org/10.1177/10225536231157129DOI Listing

Publication Analysis

Top Keywords

fibula rod
20
fibula
13
entry site
12
site fibula
8
rod
8
computed tomography
8
distal fibula
8
entry point
8
distance rod
8
posterolateral cortex
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!