A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design of customized coated dental implants using finite element analysis. | LitMetric

Background: Dental implants are used as a traditional technique to replace missing teeth. In the longterm evaluation of dental implants, the stability and durability of the implant-bone interface are crucial. Furthermore, the success of dental implants depends on several factors, such as osseointegration, implant geometry and surface topography.

Objectives: The aim of the study was to investigate the effects of coating materials on dental implants by altering several parameters, including the material used, the coating thickness, and different combinations of the cortical and cancellous bones.

Material And Methods: The coating materials used were hydroxyapatite (HAP), monticellite (MTC) and titanium nitride (TiN). The coating thickness was varied as 50 μm, 100 μm, 150 μm, and 200 μm. Five different bone combinations were used for the proposed finite element model. An axial compressive load of 150 N was applied.

Results: The FEA showed that the HAP coating material had a significant effect on minimizing the induced stress concentration for all 5 bone combinations. However, the MTC coating material had a significant effect only on 2 bone combinations (combination 2 and combination 3). Meanwhile, the TiN coating material induced higher stress values.

Conclusions: Based on finite element analysis (FEA), it was observed that the coating thickness greatly influenced the concentration of the mechanical stress. Indeed, when the coating thickness was relatively high, the stress concentration value significantly decreased.

Download full-text PDF

Source
http://dx.doi.org/10.17219/dmp/142447DOI Listing

Publication Analysis

Top Keywords

dental implants
20
coating thickness
16
finite element
12
bone combinations
12
coating material
12
coating
9
element analysis
8
coating materials
8
tin coating
8
stress concentration
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!