Objectives: Endovascular treatment has been suggested as an alternative for open surgery for type A aortic dissection, but current devices have severe anatomical limitations. This study assesses the computed tomography-based anatomical suitability of currently manufactured stent grafts as well as 2 embodiments of valve-carrying devices.
Methods: In a retrospective single-centre cohort of 200 consecutive ascending/arch operations between 2009 and 2018, a total of 112 patients with type A aortic dissections were identified and evaluated for endovascular candidacy based on the locations of the entries, the landing zone diameters/lengths and the supra-aortic vessel origins according to the anatomical instructions for use criteria of 6 commercially available (tubular, branched or fenestrated) stent grafts. Two suggested valve-carrying devices with inner branches or fenestrations for the coronary arteries and branches for the supra-aortic vessels were also evaluated.
Results: The anatomical feasibility for commercial stent grafts ranged from 4% to 21%. The main limitations were proximal landing zone diameter (considering oversizing <15%), length due to dilatation and an entry too close to the sinotubular junction. For the valve-carrying conduits, anatomical feasibility was between 31% and 80%, with the main limiting factors being the diameter of the aortic annulus and its distance to the coronary arteries.
Conclusions: The anatomical applicability of currently manufactured stent grafts for the treatment of type A aortic dissection is limited mainly by the absence of a suitable proximal landing zone in the ascending aorta and might substantially be improved by anchoring in the aortic annulus using a valve-carrying device that uses either fenestrations or branches for the coronary arteries.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10206284 | PMC |
http://dx.doi.org/10.1093/ejcts/ezad085 | DOI Listing |
Surg Infect (Larchmt)
January 2025
Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan.
Stent graft infection (SGI) caused by complex is rare. The usage of ascending-to-descending aortic bypass (ADAB) in such situations has not yet been fully discussed. Case report and literature review.
View Article and Find Full Text PDFHeart Rhythm O2
December 2024
Vanderbilt Heart and Vascular Institute, Vanderbilt University Medical Center, Nashville, Tennessee.
EJVES Vasc Forum
November 2024
Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy.
Objective: Paravisceral aortic lesions present significant challenges for endovascular treatment. This retrospective analysis of consecutively treated patients from April 2017 to June 2021 aimed to analyse the outcome of primary intra-operative embolisation of aortic complicated pseudoaneurysms and gutter channels during parallel graft (PG) repair of paravisceral symptomatic aortic pseudoaneurysms.
Methods: Patients with symptomatic pseudoaneurysms of the paravisceral aorta treated with PGs using chimney or periscope configurations were included.
J Clin Exp Hepatol
November 2024
Department of Radiodiagnosis, All India Institute of Medical Sciences, Bhubaneswar, Odisha, 751019, India.
Suspicion of vascular injury during endoscopic retrograde cholangiopancreatography (ERCP) should be raised in the event of intraprocedural bleeding, persistent hyperbilirubinemia, and sepsis despite biliary stenting. Most inadvertent portal vein (PV) cannulations during ERCP are innocuous, and mere withdrawal of guidewire and catheter suffices. However, unintentional PV stenting, particularly with larger metallic stents, increases the likelihood of significant bleeding.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai 20032, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!