The influence of printing angle on color and translucency of 3D printed resins for dental restorations.

Dent Mater

Department of Stomatology, Faculty of Dentistry, Colegio Máximo, University of Granada, Campus de Cartuja s/n, 18071 Granada, Spain.

Published: April 2023

Objectives: To evaluate the influence of printing orientation on color and translucency of 3D printing restorative resins.

Methods: Four 3D printing resin systems in the available shades (DFT-Detax Freeprint Temp- A1, A2,A3; FP-Formlabs Permanent Crown- A2,A3,B1,C2; FT- Formlabs Temporary CB- A2,A3,B1,C2; GCT-GC Temporary- Light, Medium) were evaluated. Three samples (10×10×1.2 mm) from each material were printed at two different printing orientations (0° and 90°) and polished to 1.00 ± 0,01 mm of thickness. Spectral reflectance was measured against black background using a calibrated spectroradiometer, CIE D65 standard illuminant and the 45°/0°geometry. Color and translucency differences were evaluated using CIEDE2000 metric (ΔE) and 50:50% perceptibility (PT and TPT) and acceptability (AT and TAT) thresholds.

Results: In general, color changes due to printing orientation at (0° and 90°) were mainly produced by ΔL* or ΔC* . ΔE were above PT for all DFT shades, FP-B1, FP-C2, FT-A2 and FT-B1. Only for DFT-1, ΔE was above AT. ΔRTP values were above TPT for DFT-A1, DFT-A3, FP-B1 and FT-B1, but lower than TAT. The direction of the changes in translucency (ΔRTP) depends on the material and shade.

Significance: The selection of building orientation (0° and 90°) for the 3D printed resins influence the visual color and translucency and therefore their esthetic appearance. These aspects should be considered when printing dental restorations using the evaluated materials.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2023.03.011DOI Listing

Publication Analysis

Top Keywords

color translucency
16
0° 90°
12
influence printing
8
printed resins
8
dental restorations
8
printing orientation
8
orientation 0°
8
printing
6
color
5
translucency
5

Similar Publications

We report a method to directly 3-D print complex heterogeneous optical phantoms with programmable tissue-mimicking absorption and scattering properties. The proposed approach utilizes commercially available multi-color mixing extruders and off-the-shelf polylactic acid (PLA) filaments, making this technique low-cost and broadly accessible. We systematically characterized optical properties, including both absorption and reduced scattering coefficients, at a wide range of mixing ratios of gray, white and translucent filaments and validated our hypothesis of a linear-mixing model between the filament mixing ratios and the resulting optical properties.

View Article and Find Full Text PDF

Objective: To evaluate color masking and relative translucency parameter (RTP) of increasing dentin thicknesses from different resin composites, with or without opacifiers, on a veneer dental preparation and resin disks.

Material And Methods: Artificial darkened lateral incisors with 1mm-thick veneers preparations were used to evaluate color masking of different resinous materials, with or without opacifiers: IPS Empress Direct (ED) with or without ED Opaque; and Essentia (ES) with or without ES Masking Liner. For the RTP test; disc-shaped specimens were performed and evaluated with a spectrophotometer (VITA Easyshade) against black and C4 backgrounds.

View Article and Find Full Text PDF

This study evaluated the effect of grinding and finishing treatments (polishing or glaze) on the color stability, translucency and opalescence of a translucent zirconia (3Y-TZP) after immersion in red wine. Discs (Ø= 12 mm; thickness 0.8 mm) of 3Y-TZP (Zenostar T, Ivoclar AG) were randomly allocated (n= 8) according to the surface treatment factor: Ctrl - as-sintered; Gr - grinding with diamond bur #4219; Gr + Pol - grinding followed by polishing; Gr + Gl - grinding followed by glaze.

View Article and Find Full Text PDF

Background/objectives: Hidrocystomas, eccrine and apocrine, are rare cystic lesions that form benign tumors of the sweat glands. This study aimed to describe the clinical features of hidrocystomas and evaluate the role of non-invasive imaging techniques, including dermoscopy, Line-field Confocal Optical Coherence Tomography (LC-OCT), Reflectance Confocal Microscopy (RCM), and Ultra-High-Frequency Ultrasound (UHFUS), in their diagnosis.

Methods: In total, seven cases of hidrocystomas were collected from the Dermatologic Clinic of the University of Siena, Italy.

View Article and Find Full Text PDF

Objectives: To assess the clinical performance of tooth-supported 3-unit fixed dental prostheses (FDPs) made from shade-graded monolithic 5Y-PSZ (partly stabilized zirconia) zirconia in terms of survival rate and the quality of restorations based on modified FDI criteria over three-years.

Materials And Methods: High-translucent shade-graded monolithic zirconia (Lava Esthetic, Solventum Dental Solutions) was used to manufacture maxillary or mandibular three-unit FDPs in the posterior region (N = 22) employing subtractive milling system (Amann Girrbach). All FDPs were bonded with a universal resin cement (Rely X Universal, Solventum Dental Solutions) and evaluated 4 weeks after cementation (baseline) and after 1, 2, and 3 years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!