Bronchial Safety After Pulsed Field Ablation for Paroxysmal Atrial Fibrillation.

Circ Arrhythm Electrophysiol

Department of Electrophysiology (A.F., N.R., S.H., D.H., A.E., J.B., E.R., K.N.), Alfried Krupp Krankenhaus, Essen, Germany.

Published: April 2023

Background: Thermal left atrial ablation can cause bronchial damage. Pulsed field ablation (PFA) is a novel, nonthermal ablation modality for paroxysmal atrial fibrillation. We report on bronchial effects after pulmonary vein isolation using PFA for paroxysmal atrial fibrillation.

Methods: A computed tomography scan showing the respiratory tract adjacent to the left atrial was obtained. Oral anticoagulation was interrupted on procedure day. Peri-procedurally, patients received heparin with an activated clotting time goal of >350 seconds. All pulmonary veins were individually isolated with a 13F steerable sheath and a pentaspline PFA catheter using either a straight-tip or J-tip guide wire. The J-tip guide wire patients were added to test the hypothesis that the straight-tip guidewire was associated with bleeding complications. One day afterward, bronchoscopy was performed. Serial hemoglobin levels were measured during 30-day follow-up.

Results: In 2 series of 30 patients, PFA was performed, with all pulmonary veins acutely isolated. Clinical course was uneventful, no patient had chest discomfort, coughing, or hemoptysis. All patients underwent uncomplicated bronchoscopy, without thermal lesions or ulcers. In 12 out of 30 (40%) straight-tip guide wire patients, small amounts of old blood without active bleeding were seen in multiple segments. All hemoglobin levels remained clinically stable. At 30-day follow-up, all patients were asymptomatic.

Conclusions: Pulmonary vein isolation using PFA for paroxysmal atrial fibrillation does not cause thermal lesions in the bronchial system. Use of a straight-tip, extrastiff guide wire for the over-the-wire PFA catheter can lead to asymptomatic bleeding in the bronchial system without clinical relevance at 30-day follow-up, opposite to use of a J-tip guide wire.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.122.011547DOI Listing

Publication Analysis

Top Keywords

guide wire
20
paroxysmal atrial
16
atrial fibrillation
12
j-tip guide
12
pulsed field
8
field ablation
8
left atrial
8
pulmonary vein
8
vein isolation
8
isolation pfa
8

Similar Publications

Physical Simulation Experiment on the Rock Breaking Efficiency of Pulse Type Controllable Shock Wave.

ACS Omega

December 2024

Shenmu Ningtiaota Mining Company, Shaanxi Coal and Chemical Industry Group, Shenmu, Shaanxi 719300, China.

Given that conducting controllable shock wave tests in actual rock formations underground in coal mines affects coal mine production with the parameters required for equipment design and incurs significant costs, a series of ground tests were conducted separately. First, the impact of energy storage on rock breaking efficiency was analyzed. Then, physical simulation experiments were conducted on the differential efficiency of controllable shock waves on high-strength cement, sandstone, granite, solid granite, and limestone.

View Article and Find Full Text PDF

Transjugular transcatheter edge-to-edge mitral valve repair in a patient with functional mitral regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.

Background: Transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is primarily performed using the transfemoral approach. However, when this approach is not feasible, the transjugular approach can be used as an alternative.

Case Summary: A 57-year-old man presented with heart failure and persistent New York Heart Association class IV symptoms, refractory to guideline-directed medical therapy, intravenous therapy, and intra-aortic balloon pumping.

View Article and Find Full Text PDF

Aim: This report highlights successful management of a rare case of a mandibular premolar with Oehler's Type IIIb Dens Invaginatus (DI) and peri-invagination periodontitis with guided intentional replantation (IR) without root canal treatment.

Methods: A 22-year-old female patient reported with discomfort and a sinus tract associated with tooth #21. Clinical examination and cone beam computed tomography revealed tooth #21 had an Oehler's Type IIIb DI with peri-invagination periodontitis.

View Article and Find Full Text PDF

Takayasu arteritis is a well-established medical entity involving inflammatory changes in large arteries. We describe a characteristic case of Takayasu arteritis, in a young woman with significant renal artery stenosis, presenting with hypertensive urgency. Unsuccessful guide wire passage due to fibrotic septae in lumen of the left renal artery necessitated an innovative interventional approach, using an IMA-guide catheter and a UB3 coronary guidewire to cross the lesions, followed by placement of a coronary drug eluting stent, with an aim to avoid restenosis.

View Article and Find Full Text PDF

Background: Severe vessel tortuosity may prevent a microcatheter from reaching a distal vessel. However, the Double-Wire Technique (DWT) may facilitate the procedure. The present study evaluated the feasibility and safety of guiding a 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!