Tibiotalocalcaneal Arthrodesis: A Retrospective Comparison Between Nails and Lateral Locking Plate Complications.

Foot Ankle Orthop

Lab Prof Manilo Mario Marco Napoli, Department of Orthopedic Surgery, Faculdade de Medicina, Universidade de São Paulo, Sao Paulo, SP, Brazil.

Published: January 2023

Background: Tibiotalocalcaneal arthrodesis is a well-established procedure to treat some hindfoot diseases. Currently, the most used implants are retrograde intramedullary nails and locking plates combined with lag screws, but there are few articles comparing differences regarding the complications.

Methods: We have retrospectively analyzed the medical records and the radiographs of patients older than 18 years who underwent this procedure in our service between 2005 and 2019 through retrograde intramedullary nails or lateral locking plates and compression screws with at least 12 months of follow-up and with no history of osteomyelitis in these bones.

Results: We evaluated a total of 67 patients; of these, 48 received retrograde intramedullary nail implants and 19 received locking plates and compression screws. The overall mean age was 48 years; the median follow-up time was 64.3 months. The complication rate was 60.4% for the intramedullary nail procedure and 52.6% for the locking plate combined with compression screws procedure.

Conclusion: No significant differences were found in the complication rates between the 2 implants.

Level Of Evidence: Level V, Case series.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9996735PMC
http://dx.doi.org/10.1177/24730114231157719DOI Listing

Publication Analysis

Top Keywords

retrograde intramedullary
12
locking plates
12
compression screws
12
tibiotalocalcaneal arthrodesis
8
nails lateral
8
lateral locking
8
locking plate
8
intramedullary nails
8
plates compression
8
intramedullary nail
8

Similar Publications

Introduction: Intramedullary femoral nails (IMFNs) need to be removed for subsequent joint replacement, refracture, nonunion, or infection. The tools used to extract newer IMFNs may not be suited for removal of older implants, especially if broken. The purpose of this study was to describe a novel technique in femoral nail extraction when primary measures fail and a report on 6 cases where it was used.

View Article and Find Full Text PDF

Introduction: The radial neck fractures in children are uncommon injures and more so in the settings of an associated elbow dislocation. Radial neck fracture, with 90° posterior rotation of the articular surface with respect to its normal axis, is a characteristic feature of rare Jeffery type 2 injury. This injury pattern is reported as sporadic reports or small series in the literature.

View Article and Find Full Text PDF

Introduction: Extra-articular deformity is that located proximal to the femoral epicondyles or distal to the neck of the fibula. In patients with gonarthrosis associated with extra-articular deformity, a different evaluation and approach will be necessary at the time of planning the arthroplasty. 3D planning and printing techniques have had a major impact on pre-operative planning, allowing the production of custom guides at low cost and in an accessible way.

View Article and Find Full Text PDF

Introduction: Delayed union, non-union, and unstable fixation can lead to fatigue fractures of orthopedic implants. Breakages typically occur at the fracture site or locking screw insertion, acting as stress concentration foci. This case report highlights a rare instance of a 3-part broken proximal femoral nail (PFN), extracted using a corticotomy-assisted method without knee joint violation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!