Large field-of-view short-wave infrared metalens for scanning fiber endoscopy.

J Biomed Opt

University of Washington, Department of Electrical and Computer Engineering, Seattle, Washington, United States.

Published: September 2023

AI Article Synopsis

  • The scanning fiber endoscope (SFE) is a small imaging device crucial for diagnosing cardiovascular diseases, currently using a refractive lens but potentially improved with a thinner alternative called a metalens.
  • A transmissive metalens operating at 1310 nm was developed to enhance resolution and shorten the device length compared to traditional methods.
  • Results showed that the metalens-based SFE offers comparable resolution and field-of-view while significantly minimizing the optical track, indicating a promising direction for advanced endoscopic applications.

Article Abstract

Significance: The scanning fiber endoscope (SFE), an ultrasmall optical imaging device with a large field-of-view (FOV) for having a clear forward view into the interior of blood vessels, has great potential in the cardiovascular disease diagnosis and surgery assistance, which is one of the key applications for short-wave infrared biomedical imaging. The state-of-the-art SFE system uses a miniaturized refractive spherical lens doublet for beam projection. A metalens is a promising alternative that can be made much thinner and has fewer off-axis aberrations than its refractive counterpart.

Aim: We demonstrate a transmissive metalens working at 1310 nm for a forward viewing endoscope to achieve a shorter device length and better resolution at large field angles.

Approach: We optimize the metalens of the SFE system using Zemax, fabricate it using e-beam lithography, characterize its optical performances, and compare them with the simulations.

Results: The SFE system has a resolution of at the center of field (imaging distance 15 mm), an FOV of , and a depth-of-focus of , which are comparable with a state-of-the-art refractive lens SFE. The use of the metalens reduces the length of the optical track from 1.2 to 0.86 mm. The resolution of our metalens-based SFE drops by less than a factor of 2 at the edge of the FOV, whereas the refractive lens counterpart has a times resolution degradation.

Conclusions: These results show the promise of integrating a metalens into an endoscope for device minimization and optical performance improvement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9997523PMC
http://dx.doi.org/10.1117/1.JBO.28.9.094802DOI Listing

Publication Analysis

Top Keywords

sfe system
12
large field-of-view
8
short-wave infrared
8
scanning fiber
8
refractive lens
8
metalens
6
sfe
6
field-of-view short-wave
4
infrared metalens
4
metalens scanning
4

Similar Publications

Effect of sulfidogenesis on ferrihydrite geochemistry and associated arsenic fate.

Environ Pollut

January 2025

State Environmental Protection Key Laboratory of Integrated Surface Water-Groundwater Pollution Control, School of Environmental Science and Engineering, Southern University of Science and Technology, Shenzhen, 518055, China. Electronic address:

Article Synopsis
  • - The study investigates how arsenic behaves in groundwater, focusing on its interaction with ferrihydrite and sulfide, revealing that the order of these interactions significantly affects arsenic's fate.
  • - Batch experiments showed that at low sulfide levels, ferrihydrite helps immobilize arsenic, while high sulfide levels initially release arsenic but can later lead to its re-immobilization by forming secondary minerals like magnetite.
  • - Findings indicate that the formation of different mineral types impacts arsenic adsorption capacities, with amorphous minerals hindering arsenic retention and crystalline minerals enhancing its immobilization, thereby shedding light on the geochemistry of iron, sulfur, and arsenic in groundwater.
View Article and Find Full Text PDF
Article Synopsis
  • - Hydroxyapatite (HAP) is widely used in medical fields for bone repair and implants, and recent studies are focusing on making orthopedic implants more biocompatible with HAP.
  • - The research combines HAP with a lipid matrix to enhance the characteristics of poly(lactic acid) (PLA) implants, utilizing the Langmuir-Blodgett method for effective deposition on PLA surfaces.
  • - Results show that a 5:1 mixture of dihexadecyl phosphate (DHP) and HAP improves the surface properties of PLA, potentially leading to better integration into bone and fewer bacteria adhering to the implants.
View Article and Find Full Text PDF

This study evaluated the effects of two polishing systems, OptraGloss (G; one-step) and OptiDisc (D; multi-step), on surface roughness (SR), contact angle (CA), surface free energy (SFE), and bacterial adhesion on three single-shade composite resins: Omnichroma (O), ZenChroma (Z), and Charisma Diamond One (C). Data for SR, CA, SFE, and adhesion of Streptococcus mutans (S. mutans) and Streptococcus mitis (S.

View Article and Find Full Text PDF

The lipophilic, bioaccumulative, persistent nature of Tetrabromobisphenol A (TBBPA) contributes to its widespread detection in various environmental media, posing significant negative implications for the living environment and human health. In this study, a reduction system and a reduction-oxidation sequential reaction system were developed using a magnetic core-shell bimetallic amendment (S-Fe/Co@GC) to investigate the degradation and mineralization properties of TBBPA. Additionally, the degradation mechanism and degradation pathway of TBBPA in various systems were analyzed.

View Article and Find Full Text PDF

Degradation Type-Aware Image Restoration for Effective Object Detection in Adverse Weather.

Sensors (Basel)

September 2024

College of Electronics and Information Engineering, Sichuan University, Chengdu 610065, China.

Despite significant advancements in CNN-based object detection technology, adverse weather conditions can disrupt imaging sensors' ability to capture clear images, thereby adversely impacting detection accuracy. Mainstream algorithms for adverse weather object detection enhance detection performance through image restoration methods. Nevertheless, the majority of these approaches are designed for a specific degradation scenario, making it difficult to adapt to diverse weather conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!