Electrolyte and acid-base disorders are frequently encountered in patients with malignancy, either due to cancer itself or as a complication of its therapy. However, spurious electrolyte disorders can complicate the interpretation and management of these patients. Several electrolytes can be artifactually increased or decreased such that the serum electrolyte values do not correspond to their actual systemic levels, potentially resulting in extensive diagnostic investigations and therapeutic interventions. Examples of spurious derangements include pseudohyponatremia, pseudohypokalemia, pseudohyperkalemia, pseudohypophosphatemia, pseudohyperphosphatemia, and artifactual acid-base abnormalities. Correctly interpreting these artifactual laboratory abnormalities is imperative for avoiding unnecessary and potentially harmful interventions in cancer patients. The factors influencing these spurious results also must be recognized, along with the steps to minimize them. We present a narrative review of commonly reported pseudo electrolyte disorders and describe strategies to exclude erroneous interpretations of these laboratory values and avoid pitfalls. Awareness and recognition of spurious electrolyte and acid-base disorders can prevent unnecessary and harmful treatments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10491742 | PMC |
http://dx.doi.org/10.1053/j.ajkd.2023.01.441 | DOI Listing |
J Med Case Rep
June 2024
National Public Health Laboratory (NPHL), Kathmandu, Nepal.
Background: Glycated hemoglobin is a well-known marker for evaluating long-term glycemic control. However, the accuracy of glycated hemoglobin measurement can be affected by the presence of hemoglobin variants, which makes the determination and interpretation of glycated hemoglobin values in terms of glycemic control not only difficult but also misleading. Here we present the first ever case of a patient with type 2 diabetes with hemoglobin E from Nepal, diagnosed incidentally because of spurious glycated hemoglobin levels.
View Article and Find Full Text PDFVet Clin Pathol
September 2024
Department of Veterinary Medicine, Queen's Veterinary School Hospital, University of Cambridge, Cambridge, UK.
A 3-year-old male neutered domestic shorthair cat presented with lethargy, hyporexia, and pyrexia of unknown origin. Biochemical analysis using a Beckman Coulter AU480 demonstrated marked increases in creatine kinase and aspartate aminotransferase, indicative of severe muscle injury, with concurrent presumptive myoglobinuria on urinalysis. A marked, non-physiologic increase in measured bicarbonate and resultant negative anion gap was documented; however, calculated bicarbonate obtained via a point-of-care blood gas analyzer was within normal limits.
View Article and Find Full Text PDFVet Clin Pathol
June 2024
Department of Veterinary Clinical Sciences, College of Veterinary Medicine, University of Minnesota, Saint Paul, Minnesota, USA.
A 3-year-old male neutered domestic shorthair cat and a 2-year-old male neutered Labrador-mix dog were separately presented to the Veterinary Medical Center for evaluation after sustaining significant muscle trauma due to a dog attack and seizure activity, respectively. In both cases, biochemical analysis was consistent with rhabdomyolysis. Additionally, a markedly increased measured serum bicarbonate concentration and negative calculated anion gap were observed.
View Article and Find Full Text PDFSpurious hyperphosphatemia, a rare occurrence, typically arises from substances in a patient's blood interfering with the colorimetric method for serum phosphate measurement. We present a case of factitious hyperphosphatemia caused by alteplase-contaminated blood samples in an 88-year-old CKD patient on hemodialysis, leading to misleadingly high phosphorus levels. Thorough investigations ruled out other etiologies, highlighting the necessity of stringent adherence to blood collection protocols to prevent sample contamination and avert erroneous laboratory results.
View Article and Find Full Text PDFBiosensors (Basel)
December 2023
Biomolecular Physics Department, Babeş-Bolyai University, Kogălniceanu 1, 400084 Cluj Napoca, Romania.
Water samples from two naturally hypersaline lakes, renowned for their balneotherapeutic properties, were investigated through a pilot SERS monitoring program. Nanotechnology-based techniques were employed to periodically measure the ultra-sensitive SERS molecular characteristics of the raw water-bearing microbial community and the inorganic content. Employing the Pearson correlation coefficient revealed a robust linear relationship between electrical conductivity and pH and Raman and SERS spectral data of water samples, highlighting the interplay complexity of Raman/SERS signals and physicochemical parameters within each lake.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!