A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Electronic Cigarette Liquid pH on Retention of 11C-Nicotine in a Respiratory Tract Model. | LitMetric

Introduction: Based on our preliminary 11C-nicotine positron emission tomography (PET) imaging studies in humans, we speculated that greater deposition of nicotine in the respiratory tract from electronic cigarettes compared to combustible cigarettes could result from the alkaline pH of typical aerosol-producing electronic cigarette liquids (e-liquids). To address this hypothesis, we assessed the effect of e-liquid pH on the retention of nicotine in vitro using 11C-nicotine, PET, and a human respiratory tract model of nicotine deposition.

Aims And Methods: A single 2-second 35-mL puff was delivered to a human respiratory tract cast from a 2.8-Ohm cartomizer at 4.1 volts. Immediately after the puff, a 2-second 700-mL air wash-in volume was administered. E-liquids (glycerol and propylene glycol 50/50 vol/vol) containing 24 mg/mL nicotine were mixed with 11C-nicotine. Deposition (retention) of nicotine was assessed using a GE Discovery MI DR PET/CT scanner. Eight e-liquids with different pH values (range 5.3-9.6) were investigated. All experiments were performed at room temperature and at a relative humidity of 70%-80%.

Results: Retention of nicotine in the respiratory tract cast was pH dependent and the pH-sensitive component of the retention was well described by a sigmoid curve. In total, 50% of the maximal pH-dependent effect was observed at pH 8.0, which is close to the pKa2 of nicotine.

Conclusions: The retention of nicotine in the respiratory tract conducting airways is dependent on the e-liquid pH. Lowering the e-liquid pH reduces retention of nicotine. Nonetheless, reduction of the pH below 7 has little effect, consistent with the pKa2 of protonated nicotine.

Implications: Similar to combustible cigarettes, the retention of nicotine in the human respiratory tract from consumption of electronic cigarettes may have some health consequences and affect nicotine dependence. Here we demonstrated that the retention of nicotine in the respiratory tract is dependent on the e-liquid pH, and lowering pH reduces retention of nicotine in conducting airways of the respiratory tract. Therefore, e-cigarettes with low pH values would result in reduced respiratory tract nicotine exposure and faster delivery of nicotine to the central nervous system (CNS). The latter can be associated with e-cigarette abuse liability and the effectiveness of e-cigarettes as substitutes for combustible cigarettes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10256878PMC
http://dx.doi.org/10.1093/ntr/ntad039DOI Listing

Publication Analysis

Top Keywords

respiratory tract
40
retention nicotine
32
nicotine respiratory
16
nicotine
14
combustible cigarettes
12
human respiratory
12
retention
10
respiratory
10
tract
10
electronic cigarette
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!