A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bioluminescent-Triple-Enzyme-Based Biosensor with Lactate Dehydrogenase for Non-Invasive Training Load Monitoring. | LitMetric

Bioluminescent-Triple-Enzyme-Based Biosensor with Lactate Dehydrogenase for Non-Invasive Training Load Monitoring.

Sensors (Basel)

Department of Biophysics, Institute of Fundamental Biology and Biotechnology, Siberian Federal University, 660041 Krasnoyarsk, Russia.

Published: March 2023

Saliva is one of the most significant biological liquids for the development of a simple, rapid, and non-invasive biosensor for training load diagnostics. There is an opinion that enzymatic bioassays are more relevant in terms of biology. The present paper is aimed at investigating the effects of saliva samples, upon altering the lactate content, on the activity of a multi-enzyme, namely lactate dehydrogenase + NAD(P)H:FMN-oxidoreductase + luciferase (LDH + Red + Luc). Optimal enzymes and their substrate composition of the proposed multi-enzyme system were chosen. During the tests of the lactate dependence, the enzymatic bioassay showed good linearity to lactate in the range from 0.05 mM to 0.25 mM. The activity of the LDH + Red + Luc enzyme system was tested in the presence of 20 saliva samples taken from students whose lactate levels were compared by the Barker and Summerson colorimetric method. The results showed a good correlation. The proposed LDH + Red + Luc enzyme system could be a useful, competitive, and non-invasive tool for correct and rapid monitoring of lactate in saliva. This enzyme-based bioassay is easy to use, rapid, and has the potential to deliver point-of-care diagnostics in a cost-effective manner.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007358PMC
http://dx.doi.org/10.3390/s23052865DOI Listing

Publication Analysis

Top Keywords

ldh red
12
red luc
12
lactate dehydrogenase
8
training load
8
saliva samples
8
luc enzyme
8
enzyme system
8
lactate
7
bioluminescent-triple-enzyme-based biosensor
4
biosensor lactate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!