Broadband Dielectric Spectroscopy with a Microwave Ablation Antenna.

Sensors (Basel)

Department of Information Engineering, Electronics, and Telecommunications, Sapienza University, Piazzale Aldo Moro 5, 00185 Rome, Italy.

Published: February 2023

Microwave ablation is a technique used to treat tumorous tissue. Its clinical use has been greatly expanding in the last few years. Because the design of the ablation antenna and the success of the treatment greatly depend on the accurate knowledge of the dielectric properties of the tissue being treated, it is highly valuable to have a microwave ablation antenna that is also able to perform in-situ dielectric spectroscopy. In this work, an open-ended coaxial slot ablation antenna design operating at 5.8 GHz is adopted from previous work, and its sensing abilities and limitations are investigated in respect of the dimensions of the material under test. Numerical simulations were performed to investigate the functionality of the floating sleeve of the antenna and to find the optimal de-embedding model and calibration option for obtaining accurate dielectric properties of the area of interest. Results show that, as in the case of the open-ended coaxial probe, the accuracy of the measurement greatly depends on the likeness between the calibration standards' dielectric properties and the material under test. Finally, the results of this paper clarify to which extent the antenna can be used to measure dielectric properties and paves the way to future improvements and the introduction of this functionality into microwave thermal ablation treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007348PMC
http://dx.doi.org/10.3390/s23052579DOI Listing

Publication Analysis

Top Keywords

ablation antenna
16
dielectric properties
16
microwave ablation
12
dielectric spectroscopy
8
open-ended coaxial
8
material test
8
ablation
6
antenna
6
dielectric
5
broadband dielectric
4

Similar Publications

: To evaluate the efficacy and safety of the Surgnova Dophi™ M150E microwave ablation system in a prospective single-center observational study. : A cohort of 50 patients with 77 primary or secondary liver tumors underwent CT-navigated stereotactic percutaneous microwave ablation with curative intention using the Surgnova Dophi™ M150E system. The endpoints were primary technique efficacy (PTE), number of complications, ablation defect dimensions, and sphericity index compared to previously reported findings.

View Article and Find Full Text PDF

Microwave ablation is a therapeutic technique that kills tumors by inducing heat generation in biological tissue through microwave emissions. Microwave ablation is a minimally invasive treatment technique, which has the advantage of treating deeply located tumors with less bleeding than traditional surgical techniques. In this study, the therapeutic effect of microwave ablation was analyzed from the perspective of the temperature range where apoptosis and necrosis occur.

View Article and Find Full Text PDF

Microwave ablation is becoming a standard procedure for treating tumors based on heat generation, causing an elevation in the tissue temperature level from 50 to 60 °C, causing tissue death. Microwave ablation is associated with uniform cell killing within ablation zones, multiple-antenna capability, low complication rates, and long-term survival. Several reports have demonstrated that multiple-antenna microwave ablation is a promising strategy for safely, rapidly, and effectively treating large tumors.

View Article and Find Full Text PDF

Background: Quantitative real-time MRI-based temperature mapping techniques are hampered by abdominal motion. Intrascan motion can be reduced by rapid acquisition sequences such as 2D echo planar imaging (EPI), and inter-scan organ displacement can be compensated by image processing such as optical flow (OF) algorithms. However, motion field estimation can be seriously affected by local variation of signal intensity on magnitude images inherent to tissue heating, potentially leading to erroneous temperature estimates.

View Article and Find Full Text PDF
Article Synopsis
  • This study evaluated how microwave power levels and antenna angles affect tumor seeding and ablation zone size using a liver model with simulated tumors.
  • Results showed that low-power microwave ablation (75 W) significantly reduced the incidence of contrast leakage compared to high-power (100 W), with 23.8% vs. 85% leakage rates respectively.
  • Ultimately, the low-power protocol was found to be better at minimizing the risk of tumor seeding, while not affecting the size of the ablation zone or the effectiveness based on antenna orientation.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!