The importance of monitoring the electron density uniformity of plasma has attracted significant attention in material processing, with the goal of improving production yield. This paper presents a non-invasive microwave probe for in-situ monitoring electron density uniformity, called the Tele-measurement of plasma Uniformity via Surface wave Information (TUSI) probe. The TUSI probe consists of eight non-invasive antennae and each antenna estimates electron density above the antenna by measuring the surface wave resonance frequency in a reflection microwave frequency spectrum (S11). The estimated densities provide electron density uniformity. For demonstration, we compared it with the precise microwave probe and results revealed that the TUSI probe can monitor plasma uniformity. Furthermore, we demonstrated the operation of the TUSI probe beneath a quartz or wafer. In conclusion, the demonstration results indicated that the TUSI probe can be used as an instrument for a non-invasive in-situ method for measuring electron density uniformity.