Self-healing materials offer a potential solution to the problem of damage to fibre-reinforced plastics (FRPs) by allowing for the in-service repair of composite materials at a lower cost, in less time, and with improved mechanical properties compared to traditional repair methods. This study investigates for the first time the use of poly(methyl methacrylate) (PMMA) as a self-healing agent in FRPs and evaluates its effectiveness both when blended with the matrix and when applied as a coating to carbon fibres. The self-healing properties of the material are evaluated using double cantilever beam (DCB) tests for up to three healing cycles. The blending strategy does not impart a healing capacity to the FRP due to its discrete and confined morphology; meanwhile, coating the fibres with the PMMA results in healing efficiencies of up to 53% in terms of fracture toughness recovery. This efficiency remains constant, with a slight decrease over three subsequent healing cycles. It has been demonstrated that spray coating is a simple and scalable method of incorporating a thermoplastic agent into an FRP. This study also compares the healing efficiency of specimens with and without a transesterification catalyst and finds that the catalyst does not increase the healing efficiency, but it does improve the interlaminar properties of the material.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006897PMC
http://dx.doi.org/10.3390/polym15051114DOI Listing

Publication Analysis

Top Keywords

polymethyl methacrylate
8
properties material
8
healing cycles
8
healing efficiency
8
healing
7
methacrylate healing
4
healing agent
4
agent carbon
4
carbon fibre
4
fibre reinforced
4

Similar Publications

Purpose: Photon counting detectors offer promising advancements in computed tomography (CT) imaging by enabling the quantification and three-dimensional imaging of contrast agents and tissue types through simultaneous multi-energy projections from broad X-ray spectra. However, the accuracy of these decomposition methods hinges on precise composite spectral attenuation values that one must reconstruct from spectral micro-CT. Errors in such estimations could be due to effects such as beam hardening, object scatter, or detector sensor-related spectral distortions such as fluorescence.

View Article and Find Full Text PDF

Purpose: To evaluate the long-term outcomes of enucleation without conjunctival closure in a large patient cohort.

Methods: A retrospective chart review was conducted from January 2011 to January 2024, examining 144 eyes of 143 patients who underwent enucleation without conjunctival closure by a single oculoplastic surgeon. Data collected included patient demographics, indications for surgery, implant types, and complications.

View Article and Find Full Text PDF

Very high heat is generated during the polymerization of poly (methyl methacrylate) (PMMA) bone cement, which is used for implant fixation in orthopedic surgery. As such, it has been suggested that irrigating the bone cement layer in the surgical site with a saline solution is a way of cooling the layer. In this study, we aimed to determine the influence of irrigation with a saline solution on the flexural strength and the microstructure of the test specimens of two PMMA bone cement brands: Simplex P and FIX 1.

View Article and Find Full Text PDF

Diverse analytical techniques are employed to scrutinize microplastics (MPs)─pervasive at hazardous concentrations across diverse sources ranging from water reservoirs to consumable substances. The limitations inherent in existing methods, such as their diminished detection capacities, render them inadequate for analyzing MPs of diminutive dimensions (microplastics: 1-5 μm; nanoplastics: < 1 μm). Consequently, there is an imperative need to devise methodologies that afford improved sensitivity and lower detection limits for analyzing these pollutants.

View Article and Find Full Text PDF

Innovative Polymeric Biomaterials for Intraocular Lenses in Cataract Surgery.

J Funct Biomater

December 2024

Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada.

Intraocular lenses (IOLs) play a pivotal role in restoring vision following cataract surgery. The evolution of polymeric biomaterials has been central to addressing challenges such as biocompatibility, optical clarity, mechanical stability, and resistance to opacification. This review explores essential requirements for IOL biomaterials, emphasizing their ability to mitigate complications like posterior capsule opacification (PCO) and dysphotopsias while maintaining long-term durability and visual quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!