Studies remain limited on the role of the Pfannenstiel incision in minimally invasive hepato-pancreato-biliary (HPB) surgery, especially robotic surgery. The role of various extraction sites in robotic HPB surgery should be understood. Herein, we describe the surgical techniques, outcomes, advantages, and disadvantages of the Pfannenstiel incision in robotic pancreatic surgery. Seventy patients underwent robotic pancreatectomy at our institution between September 2020 and October 2022. The Pfannenstiel incision was used for specimen retrieval in 55 patients. Advantages of the Pfannenstiel incision include less pain, cosmetic benefits, and a lower incidence of complications. Moreover, the specimen could be removed using the robotic system docked. However, all complex reconstructions should be performed intra-abdominally during robotic pancreatoduodenectomies. The incidence of mortality and postoperative pancreatic fistula (grade B) was 0% and 9.1%, respectively. During the median follow-up (11.2 months) after surgery, complications at the Pfannenstiel incision site included surgical site infection ( = 1, 1.8%) and incisional hernia ( = 1, 1.8%). The Pfannenstiel incision can be a useful option for specimen retrieval in minimally invasive HPB surgery, according to the surgeon's preferences and the patient's condition.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10004448PMC
http://dx.doi.org/10.3390/jcm12051971DOI Listing

Publication Analysis

Top Keywords

pfannenstiel incision
28
hpb surgery
12
role pfannenstiel
8
incision robotic
8
minimally invasive
8
specimen retrieval
8
incision
7
robotic
7
surgery
7
pfannenstiel
6

Similar Publications

Purpose: The primary aim of this study is to determine the rectus abdominis tendon (RAT) insertional anatomy and consequently clarify the extension of secure mobilization of the tendon from the pubic bone in the setting of anterior approaches in pelvic and acetabular reconstruction surgery.

Materials And Methods: Eleven fresh frozen cadaveric pelvises were dissected by two fellowship-trained orthopaedic trauma surgeons utilizing the anterior intrapelvic approach (AIP). The RAT at the pubic body was dissected, and its footprint on the pubic bone was defined, marked, and measured.

View Article and Find Full Text PDF

Evidence-based cesarean delivery: intraoperative management from skin incision until placental delivery (Part 8).

Am J Obstet Gynecol MFM

December 2024

Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, Thomas Jefferson University, Philadelphia, PA. Electronic address:

The goal of standardizing the technique of the routine, uncomplicated cesarean delivery (CD) is to decrease maternal morbidity while optimizing neonatal outcomes. During the procedure, a family-oriented CD is recommended. The low transverse cesarean skin incision (created with either scalpel or diathermy) is preferred with either the Joel-Cohen or Pfannenstiel methods being acceptable.

View Article and Find Full Text PDF
Article Synopsis
  • Vaginal cuff dehiscence is a rare but serious complication after total hysterectomy, with occurrences ranging from 0.032% to 1.25% and a notable mortality risk of 6 to 10%.
  • The case study follows a 59-year-old woman who experienced abdominal and pelvic pain and had bowel loops protruding from her vagina six months after a laparoscopic total hysterectomy.
  • Emergency surgery revealed the ileum prolapsing through the vaginal cuff; immediate intervention was critical to prevent life-threatening issues, emphasizing the need for awareness among surgeons and gynecologists about this complication.
View Article and Find Full Text PDF

Background: Rectal division during minimally invasive surgery including robotic assisted surgery remains challenging, with current techniques often requiring multiple stapler firings to achieve effective transection.

Aims: We propose a novel technique which allows the use of a Contour® Curved Cutter Stapler to achieve rectal division during robotic assisted surgery.

Methods: The stapler is inserted through the routinely made pfannenstiel incision and a glove, over an Alexis® port used to create an airtight seal.

View Article and Find Full Text PDF
Article Synopsis
  • The study compared the incidence of incisional hernias in patients who had their surgical specimen removed through two different incisions: Pfannenstiel incision (PI) and midline incision (MI).
  • A total of 370 patients were analyzed, and after adjusting for variables using propensity score matching, 71 patients from each group were compared, revealing that the PI method had no hernia cases while the MI method had a 14% incidence.
  • The findings suggest that using the PI for specimen extraction is better due to the significantly lower occurrence of incisional hernias and no increase in complication rates.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!