Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3051
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3053
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3053
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study aimed to evaluate a clothing prototype that incorporates sensors for the evaluation of pressure, temperature, and humidity for the prevention of pressure injuries, namely regarding physical and comfort requirements. A mixed-method approach was used with concurrent quantitative and qualitative data triangulation. A structured questionnaire was applied before a focus group of experts to evaluate the sensor prototypes. Data were analyzed using descriptive and inferential statistics and the discourse of the collective subject, followed by method integration and meta-inferences. Nine nurses, experts in this topic, aged 32.66 ± 6.28 years and with a time of profession of 10.88 ± 6.19 years, participated in the study. Prototype A presented low evaluation in stiffness (1.56 ± 1.01) and roughness (2.11 ± 1.17). Prototype B showed smaller values in dimension (2.77 ± 0.83) and stiffness (3.00 ± 1.22). Embroidery was assessed as inadequate in terms of stiffness (1.88 ± 1.05) and roughness (2.44 ± 1.01). The results from the questionnaires and focus groups' show low adequacy as to stiffness, roughness, and comfort. The participants highlighted the need for improvements regarding stiffness and comfort, suggesting new proposals for the development of sensors for clothing. The main conclusions are that Prototype A presented the lowest average scores relative to rigidity (1.56 ± 1.01), considered inadequate. This dimension of Prototype B was evaluated as slightly adequate (2.77 ± 0.83). The rigidity (1.88 ± 1.05) of Prototype A + B + embroidery was evaluated as inadequate. The prototype revealed clothing sensors with low adequacy regarding the physical requirements, such as stiffness or roughness. Improvements are needed regarding the stiffness and roughness for the safety and comfort characteristics of the device evaluated.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10001934 | PMC |
http://dx.doi.org/10.3390/ijerph20054039 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!