Endoscopic balloon sphincteroplasty is an established procedure for the extraction of bile duct stones. However, the balloon often slips during the inflation process, and its length is an impediment if the distance between the papilla and scope is limited and/or the stone is located close to the papilla. This animal experimental study aimed to evaluate the feasibility of a novel short non-slip banded balloon measuring 15-20 mm in length for sphincteroplasty. The ex vivo component of this study was conducted using porcine duodenal papilla. Miniature pigs were subjected to endoscopic retrograde cholangiography in the in vivo component. The technical success of sphincteroplasty without any slippage was the primary outcome of the study and was compared between cases managed with the non-slip banded balloon (non-slip balloon group) and conventional balloon (conventional balloon group). The technical success rate of the ex vivo component, i.e., absence of any slippage, was significantly higher in the non-slip balloon group than in the conventional balloon group with the 8-mm (96.0% vs. 16.0%, P < 0.001) and 12-mm diameter balloons (96.0% vs. 0%, P < 0.001). The technical success rate of endoscopic sphincteroplasty without slippage in the in vivo component was significantly higher in the non-slip balloon group than in the conventional balloon group (100% vs. 40%, P = 0.011). No immediate adverse events were observed in either group. The slippage rate was significantly lower with sphincteroplasty using a non-slip balloon, despite the balloon length being considerably shorter than that of conventional balloons, demonstrating its potential utility in difficult cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006090PMC
http://dx.doi.org/10.1038/s41598-023-31206-6DOI Listing

Publication Analysis

Top Keywords

balloon group
16
non-slip banded
12
banded balloon
12
vivo component
12
conventional balloon
12
balloon
10
sphincteroplasty vivo
8
technical success
8
non-slip balloon
8
group conventional
8

Similar Publications

Background: Because of the limitations in new-generation drug-eluting stents (DES), treatments advocating for non-stents with a drug-coated balloon (DCB) is now of great interest. Here, we conducted a meta-analysis to testify whether a DCB was more effective and safer than a DES in treating de novo coronary artery disease (CAD).

Methods: We searched PubMed, Embase, Cochrane Library, and Web of Science to obtain high-quality trials comparing DCB with DES for the treatment of de novo CAD.

View Article and Find Full Text PDF

Hemorrhagic shock is a significant cause of trauma-related mortality. Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a less-invasive aortic occlusion maneuver for severe hemorrhagic shock but potentially inducing oxidative stress injuries. In an animal model, this study investigated hydrogen gas inhalation therapy's potential to mitigate post-REBOA ischemia-reperfusion injuries (IRIs).

View Article and Find Full Text PDF

Objective: Berry syndrome is a group of rare congenital cardiac malformations including aortopulmonary window (APW), aortic origin of the right pulmonary artery (AORPA), interruption of the aortic arch (IAA), patent ductus arteriosus (PDA) (supplying the descending aorta) and intact ventricular septum. This paper will analyze the clinical data of 7 patients with Berry syndrome who underwent surgical treatment in our institution and discuss the one-stage surgical correction of Berry syndrome in combination with the literature.

Methods: From January 2013 to July 2024, a total of 7 children with Berry syndrome were admitted to the Cardiac Surgery Department of Beijing Children's Hospital.

View Article and Find Full Text PDF

Background: Coronary artery bypass grafting (CABG) surgery has been a widely accepted method for treating coronary artery disease. However, its postoperative complications can have a significant effect on long-term patient outcomes. A retrospective study was conducted to identify before and after surgery that contribute to postoperative stroke in patients undergoing CABG, and to develop predictive models and recommendations for single-factor thresholds.

View Article and Find Full Text PDF

Background: To evaluate the feasibility, effectiveness and assistant effect of 3D printed aortic model in the treatment on congenital coarctation of the aorta (CoA) in adolescents and adults.

Methods: From December 2018 to December 2023, a total of 10 patients with congenital coarctation of aorta underwent percutaneous balloon dilatation covered stent implantation in the department of cardiovascular surgery, Xijing Hospital. There were 6 males and 4 females whose average age was (27.

View Article and Find Full Text PDF