Background: Rates of infection after inflatable penile prosthesis range from 1% to 3%; however, a new surgical irrigation solution is Food and Drug Administration cleared as antimicrobial wound lavage and appears to be safe for patients and noncaustic during hydrophilic inflatable penile prosthesis (hIPP) dipping and irrigation.

Aim: To evaluate if 0.05% chlorhexidine (CHG) lavage is caustic to the hIPP coating and if dip adherence is dependent on time.

Methods: Preconnected hIPP devices were tested at a Coloplast research and development laboratory. The devices were soaked in the 0.05% CHG lavage solution or normal saline for 1, 15, 30, and 60 minutes. Subsequently, all parts were dried for 15 minutes in a 35 °C oven. A Congo red dye test was performed following a Coloplast-validated and Food and Drug Administration-cleared test method to ensure product reliability. Implants were then visually inspected for deleterious effects as well as dip coverage. In addition, we evaluated 0.05% CHG lavage solution vs previously published hIPP dipping solutions.

Outcomes: 0.05% CHG lavage does not appear to damage the hIPP coating, and adherence of this solution is not dependent on dip time.

Results: All components of the preconnected hydrophilic IPPs were tested for coating adherence and defects. All tested IPPs achieved a "satisfactory" coating, meaning a uniform coat without flaking or clumping. Furthermore, there were no noticeable caustic effects or differences in coating adherence between the normal saline-soaked control and 0.05% CHG-coated arms with increasing dip time. A review of the literature for 0.05% CHG lavage solutions vs previously published hIPP dipping solutions revealed that it may have some advantages over previously reported antibiotic solutions.

Clinical Implications: This study serves as a foundation to introduce 0.05% CHG lavage to the urologic literature as a potentially new "magic bullet" irrigation.

Strengths And Limitations: Major strengths of the study are that it is the first study of its kind to address the question of what dip duration should be used and whether it is scientifically reproducible. A limitation is the in vitro model, thus needing validation in a clinical setting.

Conclusion: 0.05% CHG does not appear to negatively affect the hIPP coating or differ in adherence with increasing dip time; however, long-term device performance has not been verified.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jsxmed/qdac007DOI Listing

Publication Analysis

Top Keywords

chg lavage
24
005% chg
24
inflatable penile
12
penile prosthesis
12
dip time
12
hipp dipping
12
hipp coating
12
coating adherence
12
005%
9
005% chlorhexidine
8

Similar Publications

Background: 0.05% Chlorhexidine gluconate (CHG; Irrisept [IrriMax]) is a commercial wound irrigation solution approved by the Food and Drug Administration that has seen recent adoption in the field of prosthetic urology; however, no study has evaluated whether 0.05% CHG is compatible with the minocycline-rifampin-impregnated surface (InhibiZone) of the AMS 700 penile prosthesis (Boston Scientific).

View Article and Find Full Text PDF

Background: Chlorhexidine gluconate (CHG) (0.05%) has recently been suggested as both a dip for the hydrophilic surface and an irrigation solution in the setting of penile prosthesis (PP) surgery.

Aim: The study sought to compare the antimicrobial efficacy of 0.

View Article and Find Full Text PDF

Background: Infection is the most dreaded complication of cardiac implantable electronic devices (CIEDs), particularly in patients undergoing high-risk procedures (eg, generator change, device upgrade, lead/pocket revision).

Objective: The purpose of this study was to describe the impact of chlorhexidine gluconate (CHG) pocket lavage in high-risk procedures.

Methods: Patients from a prospective multicenter registry undergoing high-risk procedures were included.

View Article and Find Full Text PDF

Background: Rates of infection after inflatable penile prosthesis range from 1% to 3%; however, a new surgical irrigation solution is Food and Drug Administration cleared as antimicrobial wound lavage and appears to be safe for patients and noncaustic during hydrophilic inflatable penile prosthesis (hIPP) dipping and irrigation.

Aim: To evaluate if 0.05% chlorhexidine (CHG) lavage is caustic to the hIPP coating and if dip adherence is dependent on time.

View Article and Find Full Text PDF

Introduction: Capsulectomy is recommended in patients with cardiac implantable electronic device (CIED) infection after transvenous lead extraction (TLE) but is time-consuming and requires extensive tissue debridement. In this study, we describe the outcomes of chlorhexidine gluconate (CHG) lavage in lieu of capsulectomy for the treatment of CIED infections.

Methods: This retrospective study included patients who underwent TLE for CIED-related infections in two institutions in Colombia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!