Background: Measuring cup orientation is time consuming and inaccurate, but orientation influences the risk of impingement and dislocation following total hip arthroplasty (THA). This study designed an artificial intelligence (AI) program to autonomously determine cup orientation, correct for pelvis orientation, and identify cup retroversion from an antero-posterior pelvic radiographs.
Methods: There were 2,945 patients between 2012 and 2019 identified to have 504 computed tomographic (CT) scans of their THA. A 3-dimensional (3D) reconstruction was performed on all CTs, where cup orientation was measured relative to the anterior pelvic plane. Patients were randomly allocated to training (4,000 x-rays), validation (511 x-rays), and testing (690 x-rays) groups. Data augmentation was applied to the training set (n = 4,000,000) to increase model robustness. Statistical analyses were performed only on the test group in their accuracy with CT measurements.
Results: AI predictions averaged 0.22 ± 0.03 seconds to run on a given radiograph. Pearson correlation coefficient was 0.976 and 0.984 for AI measurements with CT, while hand measurements were 0.650 and 0.687 for anteversion and inclination, respectively. The AI measurements more closely represented CT scans when compared to hand measurements (P < .001). Measurements averaged 0.04 ± 2.21°, 0.14 ± 1.66°, -0.31 ± 8.35°, and 6.48° ± 7.43° from CT measurements for AI anteversion, AI inclination, hand anteversion, and hand inclination, respectively. AI predictions identified 17 radiographs as retroverted with 100.0% accuracy (total retroverted, n = 45).
Conclusion: The AI algorithms may correct for pelvis orientation when measuring cup orientation on radiographs, outperform hand measurements, and may be implemented in a timely fashion. This is the first method to identify a retroverted cup from a single AP radiograph.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2023.02.076 | DOI Listing |
Surg Technol Int
January 2025
JIS Orthopedics Inc., New Albany, Ohio.
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.
View Article and Find Full Text PDFArthroplasty
January 2025
Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy.
Background: Proper positioning of a total hip arthroplasty (THA) plays a crucial role in the success and long-term survivorship of the implant. Cup positioning within the Lewinnek Safe Zone (LSZ) does not, however, avoid implant dislocation. Thus, the concept of a functional cup position has been introduced.
View Article and Find Full Text PDFBone Jt Open
January 2025
Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Japan.
Aims: Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.
Methods: We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan.
SICOT J
December 2024
The Hazeley Academy, Emperor Drive, Hazeley, Milton Keynes, MK8 0PT, United Kingdom.
Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA).
Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA).
Chem Sci
January 2025
Department Pharmazie, Ludwig-Maximilians-Universität München Butenandtstraße 5-13 Munich D-81377 Germany
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!