A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An in-vitro analysis of the accuracy of different guided surgery systems - They are not all the same. | LitMetric

Objectives: Different static computer-assisted implant surgery (sCAIS) systems are available that are based on different design concepts. The objective was to assess seven different systems in a controlled environment.

Materials And Methods: Each n = 20 implants were placed in identical mandible replicas (total n = 140). The systems utilized either drill-handles (group S and B), drill-body guidance (group Z and C), had the key attached to the drill (group D and V), or combined different design concepts (group N). The achieved final implant position was digitized utilizing cone-beam tomography and compared with the planned position. The angular deviation was defined as the primary outcome parameter. The means, standard deviation, and 95%-confidence intervals were analyzed statistically with 1-way ANOVA. A linear regression model was applied with the angle deviation as predictor and the sleeve height as response.

Results: The overall angular deviation was 1.94 ± 1.51°, the 3D-deviation at the crest 0.54 ± 0.28 mm, and at the implant tip 0.67 ± 0.40 mm, respectively. Significant differences were found between the tested sCAIS systems. The angular deviation ranged between 0.88 ± 0.41° (S) and 3.97 ± 2.01° (C) (p < .01). Sleeve heights ≤4 mm are correlated with higher angle deviations, sleeve heights ≥5 mm with lower deviations from the planned implant position.

Conclusions: Significant differences were found among the seven tested sCAIS systems. Systems that use drill-handles achieved the highest accuracy, followed by the systems that attach the key to the drill. The sleeve height appears to impact the accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.14061DOI Listing

Publication Analysis

Top Keywords

angular deviation
12
scais systems
8
design concepts
8
systems
5
deviation
5
in-vitro analysis
4
analysis accuracy
4
accuracy guided
4
guided surgery
4
surgery systems
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!