A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic value of a nanopore sequencing assay of bronchoalveolar lavage fluid in pulmonary tuberculosis. | LitMetric

Diagnostic value of a nanopore sequencing assay of bronchoalveolar lavage fluid in pulmonary tuberculosis.

BMC Pulm Med

Tuberculosis Department, Beijing Chest Hospital Affiliated to Capital Medical University, No 9, Beiguan Street, Tongzhou District, Beijing, 101149, People's Republic of China.

Published: March 2023

Background: To determine the diagnostic accuracy of a nanopore sequencing assay of PCR products from a M. tuberculosis complex-specific region for testing of bronchoalveolar lavage fluid (BALF) samples or sputum samples from suspected pulmonary tuberculosis (PTB) patients and compare the results to results obtained for MGIT and Xpert assays.

Methods: Cases with suspected PTB (n = 55) were diagnosed from January 2019 to December 2021 based on results of nanopore sequencing, MGIT culture, and Xpert MTB/RIF testing of BALF and sputum samples collected during hospitalization. Diagnostic accuracies of assays were compared.

Results: Ultimately, data from 29 PTB patients and 26 non-PTB cases were analyzed. PTB diagnostic sensitivities of MGIT, Xpert MTB/RIF, and nanopore sequencing assays were 48.28%, 41.38%, and 75.86%, respectively, thus demonstrating that nanopore sequencing provided greater sensitivity than was provided by MGIT culture and Xpert assays (P < 0.05). PTB diagnostic specificities of the respective assays were 65.38%, 100%, and 80.77%, which corresponded with kappa coefficient (κ) values of 0.14, 0.40, and 0.56, respectively. These results indicate that nanopore sequencing provided superior overall performance as compared to Xpert and MGIT culture assays and provided significantly greater PTB diagnostic accuracy than Xpert and sensitivity comparable to that of the MGIT culture assay.

Conclusion: Our findings suggest that improved detection of PTB in suspected cases was achieved using nanopore sequencing-based testing of BALF or sputum samples than was achieved using Xpert and MGIT culture-based assays, and nanopore sequencing results alone cannot be used to rule out PTB.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9996878PMC
http://dx.doi.org/10.1186/s12890-023-02337-3DOI Listing

Publication Analysis

Top Keywords

nanopore sequencing
20
sequencing assay
8
bronchoalveolar lavage
8
lavage fluid
8
pulmonary tuberculosis
8
sputum samples
8
ptb patients
8
mgit xpert
8
mgit culture
8
culture xpert
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!