Purpose: This prospective clinical study evaluated and compared the marginal and internal fit of crowns fabricated with an analog workflow and three different computer-aided design and computer-aided manufacturing (CAD-CAM) systems.

Materials And Methods: Twenty-five participants in need of a single complete-coverage molar or premolar crown were recruited in the study. Twenty-two completed the study, and three participants dropped out. Teeth were prepared according to a standardized protocol by one operator. For each participant, one final impression was made with polyether material (PP) and three intraoral scanners: CEREC Omnicam (C), Planmeca Planscan (PM), and True Definition (TR). For the PP group, crowns were fabricated with a pressable lithium disilicate ceramic, whereas for the other three groups (C, PM, and TR), crowns were designed and milled with dedicated CAD-CAM systems and materials. Marginal (vertical and horizontal) and internal discrepancies between the crowns and tooth preparation were measured at various locations with digital superimposition software. Data was analyzed for normality with Kolmogorov-Smirnov and Shapiro-Wilk tests and then compared with one-way ANOVA and Kruskal-Wallis tests.

Results: Mean vertical marginal gap values were 92.18 ± 141.41 μm (PP), 150.12 ± 138.06 μm (C), 129.07 ± 109.96 μm (PM), and 135.09 ± 112.03 μm (TR). PP group had statistically significantly smaller vertical marginal discrepancy (p = 0.001) than all other groups, whereas no significant difference was detected among the three CAD-CAM systems (C, PM, and TR). Horizontal marginal discrepancies were 104.93 ± 111.96 μm (PP), 89.49 ± 119.66 μm (C), 113.36 ± 128.49 μm (PM), and 136.39 ± 142.52 μm (TR). A significant difference was detected only between C and TR (p < 0.0001). Values for the internal fit were 128.40 ± 49.31μm (PP), 190.70 ± 69.79μm (C), 146.30 ± 57.70 μm (PM), and 168.20 ± 86.67 μm (TR). The PP group had a statistically significant smaller internal discrepancy than C (p < 0.0001) and TR groups (p = 0.001), whereas no significant difference was found compared to the PM group.

Conclusion: Posterior crowns fabricated with CAD-CAM systems showed vertical margin discrepancy greater than 120 μm. Only crowns fabricated with the conventional methodology had vertical margins below 100 μm. Horizontal marginal discrepancy was different among all groups, and only CEREC CAD-CAM was below 100 μm. Internal discrepancy was less for crowns fabricated with an analog workflow.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13675DOI Listing

Publication Analysis

Top Keywords

cad-cam systems
12
marginal internal
8
internal fit
8
analog workflow
8
workflow three
8
three cad-cam
8
prospective clinical
8
clinical study
8
crowns fabricated
8
vertical marginal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!