AI Article Synopsis

  • The study introduces a new method to measure benzothiazoles, benzotriazoles, and benzenesulfonamides in different water sources using microextraction by packed sorbent (MEPS) and advanced mass spectrometry techniques.
  • The method was optimized through experimental design and principal component analysis, achieving excellent accuracy and precision with low detection limits for the target compounds.
  • Additionally, the method was assessed for its environmental sustainability using various metrics, showing it is effective for real-world water monitoring and exposome research.

Article Abstract

This work proposes a new method for the quantification of benzothiazoles (BTs), benzotriazoles (BTRs), and benzenesulfonamides (BSAs) in tap water, river water, and wastewater. The protocol involved the use of microextraction by packed sorbent (MEPS), applied for the first time for the extraction of the target analytes, combined with programmed temperature vaporization-gas chromatography-triple quadrupole mass spectrometry (PTV-GC-QqQ-MS). Considering the synergism between MEPS extraction and PTV injection, the experimental variables affecting their performance were simultaneously optimized by "experimental design", while principal component analysis (PCA) was used to find the overall optimal working conditions. Response surface methodology was used to gain a comprehensive understanding of the effects of working variables on method performance. The developed method achieved very good linearities and satisfactory intra- and inter-day accuracies and precisions. The protocol permitted the detection of the target molecules with limit of detection (LODs) values between 0.005 and 0.85 μg/L. The green character of the procedure was evaluated using three metrics: "Analytical Eco-Scale", "Green Analytical Procedure Index" (GAPI), and "Analytical Greenness metric for sample preparation (AGREEprep). The satisfactory results obtained with real water samples demonstrate the applicability of the method for monitoring campaigns and exposome studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2023.124410DOI Listing

Publication Analysis

Top Keywords

microextraction packed
8
packed sorbent
8
programmed temperature
8
temperature vaporization-gas
8
assessment benzothiazoles
4
benzothiazoles benzotriazoles
4
benzotriazoles benzenesulfonamides
4
benzenesulfonamides environmental
4
environmental waters
4
waters optimized
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!