A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rational Design of Stapled Antimicrobial Peptides to Enhance Stability and Potency against Polymicrobial Sepsis. | LitMetric

In this work, we sought to develop a TP4-based stapled peptide that can be used to counter polymicrobial sepsis. First, we segregated the TP4 sequence into hydrophobic and cationic/hydrophilic zones and substituted the preferred residue, lysine, as the sole cationic amino acid. These modifications minimized the intensity of cationic or hydrophobic characteristics within small segments. Then, we incorporated single or multiple staples into the peptide chain, bracketing the cationic/hydrophilic segments to improve pharmacological suitability. Using this approach, we were able to develop an AMP with low toxicity and notable efficacy. In our studies, one dual stapled peptide out of the series of candidates (TP4-3: FIIXKKSXGLFKKKAGAXKKKXIKK) showed significant activity, low toxicity, and high stability (in 50% human serum). When tested in cecal ligation and puncture (CLP) mouse models of polymicrobial sepsis, TP4-3 improved survival (87.5% on day 7). Furthermore, TP4-3 enhanced the activity of meropenem against polymicrobial sepsis (100% survival on day 7) compared to meropenem alone (37.5% survival on day 7). Molecules such as TP4-3 may be well suited for a wide variety of clinical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10101059PMC
http://dx.doi.org/10.1128/spectrum.03853-22DOI Listing

Publication Analysis

Top Keywords

polymicrobial sepsis
16
stapled peptide
8
low toxicity
8
survival day
8
rational design
4
design stapled
4
stapled antimicrobial
4
antimicrobial peptides
4
peptides enhance
4
enhance stability
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!