Comparison of conjunctiva-related complications between scleral and corneal patch grafts in Ahmed glaucoma valve implantation.

Indian J Ophthalmol

Jadhavbai Nathamal Singhvi Glaucoma Services, Sankara Nethralaya Medical Research Foundation, Chennai, Tamil Nadu, India.

Published: March 2023

AI Article Synopsis

Article Abstract

Purpose: Comparison of the conjunctiva related complication rates and success rates among eyes with Ahmed glaucoma valve (AGV) implantation in which eye bank derived scleral and corneal patch grafts had been used to cover the tube.

Methods: Retrospective comparative study. Patients who underwent AGV implantation between January 2000 to December 2016 were included. Demographic, clinical data, intra and post operative data was obtained from electronic medical records. Conjunctiva related complications were divided into two groups: with and without implant exposure. Conjunctiva related complication rates, success rate, risk factors among eyes with corneal and scleral patch graft were compared.

Results: Three hundred and twenty three eyes of 316 patients underwent AGV implantation. Scleral patch graft was used in 214 eyes of 210 patients (65.9%) and corneal patch graft was used in 109 eyes of 107 patients (34%). Median follow up was 14 months. There was no significant difference in the conjunctiva related complication rate (7.3 % in corneal patch graft versus 7.0% in scleral patch graft;p=0.5) and conjunctival dehiscence rate (3.7% versus 4.6%, P = 0.7) among the two groups. Success rate was significantly higher in the corneal patch graft group versus the scleral patch graft group (98% versus 72%; p=0.001). Eyes with corneal patch graft had a higher survival rate (P = 0.01).

Conclusion: There was no significant difference in the rate of conjunctiva related complications following corneal and scleral patch grafts used to cover the AGV tube. Eyes with corneal patch graft had a higher success rate and survival rate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10229988PMC
http://dx.doi.org/10.4103/ijo.IJO_1846_22DOI Listing

Publication Analysis

Top Keywords

patch graft
32
corneal patch
28
scleral patch
20
patch
12
patch grafts
12
conjunctiva complication
12
agv implantation
12
success rate
12
eyes corneal
12
corneal
9

Similar Publications

Corneal substitutes with structural and compositional characteristics resembling those of natural corneas have attracted considerable attention. However, biomimicking the complex hierarchical organization of corneal stroma is challenging. In this study, humanized corneal stroma-like adhesive patches (HCSPs) are prepared through a multi-step process.

View Article and Find Full Text PDF

Direct Axillary Artery Cannulation as Standard Perfusion Strategy in Minimally Invasive Coronary Artery Bypass Grafting.

J Cardiovasc Dev Dis

January 2025

Department of Cardiothoracic Surgery, Heart-Thorax Center, Klinikum Fulda, University Medicine Marburg, Campus Fulda, 36043 Fulda, Germany.

Objective: Cardiopulmonary bypass (CPB) via the right axillary artery (RAA) has become an alternative perfusion strategy, especially in complex aortic procedures. This study delineates our technique and outcome with direct axillary cannulation utilizing the Seldinger technique, which we adopted as the standard perfusion strategy in the sternum-sparing minimally invasive total coronary revascularization via left anterior thoracotomy (TCRAT) using CPB.

Methods: From November 2019 to December 2023, a total of 413 consecutive patients underwent nonemergent isolated coronary artery bypass grafting (CABG) via left anterior minithoracotomy on CPB with peripheral cannulation via the RAA and cardioplegic cardiac arrest, using this technique as a default strategy in the daily routine.

View Article and Find Full Text PDF

To improve wound healing, advanced biofabrication techniques are proposed here to develop customized wound patches to release bioactive agents targeting cell function in a controlled manner. Three-dimensional (3D) bioprinted "smart" patches, based on methacrylated gellan gum (GGMA), loaded with tannic acid (TA) or L-ascorbic acid (AA) have been manufactured. To improve stability and degradation time, gellan gum (GG) was chemically modified by grafting methacrylic moieties on the polysaccharide backbone.

View Article and Find Full Text PDF

Renal dysfunction due to ischemia-reperfusion injury (IRI) is a common problem after kidney transplantation. In recent years, studies on animal models have shown that exosomes derived from mesenchymal stem cells (MSC-Exo) play an important role in treating acute kidney injury (AKI) and promoting tissue repair. The microneedle patch provides a noninvasive and targeted delivery system for exosomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!