Background: Stereoencephalography (SEEG) is becoming a widespread diagnostic procedure for drug-resistant epilepsy investigation. Techniques include frame-based and robot-assisted implantation, and more recently, frameless neuronavigated systems (FNSs). Despite its recent use, the accuracy and safety of FNS are still under investigation.

Objective: To assess in a prospective study the accuracy and safety of a specific FNS use for SEEG implantation.

Methods: Twelve patients who underwent SEEG implantation using FNS (Varioguide [Brainlab]) were included in this study. Data were collected prospectively and included demographic data, postoperative complications, functional results, and implantation characteristics (i.e., duration and number of electrodes). Further analysis included accuracy at entry point and target using measurements of the euclidean distance between planned and actual trajectories.

Results: Eleven patients underwent SEEG-FNS implantation from May 2019 to March 2020. One patient did not undergo surgery because of a bleeding disorder. The mean target deviation was 4.06 mm, and mean entry point deviation was 4.2 mm, with insular electrodes significantly more deviated. Results excluding insular electrodes showed a mean target deviation of 3.66 mm and a mean entry point deviation of 3.77 mm. No severe complications occurred; a few mild to moderate adverse events were reported (1 superficial infection, 1 seizure cluster, and 3 transient neurologic impairments). The mean implantation duration by electrodes was 18.5 minutes.

Conclusions: Implantation of depth electrodes for SEEG using FNS seems to be safe, but larger prospective studies are needed to validate these results. Accuracy is sufficient for noninsular trajectories but warrant caution for insular trajectories with statistically significantly less accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2023.02.116DOI Listing

Publication Analysis

Top Keywords

accuracy safety
12
entry point
12
implantation frameless
8
patients underwent
8
target deviation
8
point deviation
8
insular electrodes
8
accuracy
6
implantation
6
electrodes
5

Similar Publications

European ILD registry algorithm for self-assessment in interstitial lung diseases (eurILDreg ASA-ILD).

PLoS One

January 2025

European IPF/ILD Registry and Biobank (eurIPFreg/bank, eurILDreg/bank), Giessen, Germany.

Background And Aims: Predicting progression and prognosis in Interstitial Lung Diseases (ILD), especially Idiopathic Pulmonary Fibrosis (IPF) and Progressive Pulmonary Fibrosis (PPF), remains a challenge. Integrating patient-centered measurements is essential for earlier and safer detection of disease progression. Home monitoring through e-health technologies, such as spirometry and oximetry connected to smartphone applications, holds promise for early detection of ILD progression or acute exacerbations, enabling timely therapeutic interventions.

View Article and Find Full Text PDF

In a rapidly evolving healthcare environment, artificial intelligence (AI) is transforming diagnostic techniques and personalised medicine. This is also seen in osseous biopsies. AI applications in radiomics, histopathology, predictive modelling, biopsy navigation, and interdisciplinary communication are reshaping how bone biopsies are conducted and interpreted.

View Article and Find Full Text PDF

The identification of vibration and reconstruction of sound fields of plate structures are important for understanding the vibroacoustic characteristics of complex structures. This paper presents a data-physics driven (DPD) model integrated with transfer learning (DPDT) for high-precision identification and reconstruction of vibration and noise radiation of plate structures. The model combines the Kirchhoff-Helmholtz integral equation with convolutional neural networks, leveraging physical information to reduce the need for extensive data.

View Article and Find Full Text PDF

Prognostic significance and accuracy of oncologists' estimates of survival time in recurrent ovarian cancer.

Int J Gynecol Cancer

January 2025

The NHMRC Clinical Trials Centre, The University of Sydney, Sydney, NSW, Australia; Macarthur Cancer Therapy Centre, Sydney, NSW, Australia; Western Sydney University, Department of Medicine, Sydney, NSW, Australia. Electronic address:

Objective: We evaluated the accuracy of oncologists' estimates of expected survival time in recurrent ovarian cancer.

Methods: Oncologists estimated expected survival time at baseline for each patient, who were then followed up for survival time. We hypothesized that oncologists' estimates of expected survival time would be independently significant predictors of survival, unbiased (approximately equal proportions [50%] living longer versus shorter than their expected survival time), or imprecise (<30% within 0.

View Article and Find Full Text PDF

Background: High-resolution brain imaging is crucial in clinical diagnosis and neuroscience, with ultra-high field strength MRI systems ( ) offering significant advantages for imaging neuronal microstructures. However, achieving magnetic field homogeneity is challenging due to engineering faults during the installation of superconducting strip windings and the primary magnet.

Purpose: This study aims to design and optimize active superconducting shim coils for a 7 T animal MRI system, focusing on the impact of safety margin, size, and adjustability of the second-order shim coils on the MRI system's optimization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!