Background: Ablation of autonomic ectopy-triggering ganglionated plexuses (ET-GP) has been used to treat paroxysmal atrial fibrillation (AF). It is not known if ET-GP localisation is reproducible between different stimulators or whether ET-GP can be mapped and ablated in persistent AF. We tested the reproducibility of the left atrial ET-GP location using different high-frequency high-output stimulators in AF. In addition, we tested the feasibility of identifying ET-GP locations in persistent atrial fibrillation.

Methods: Nine patients undergoing clinically-indicated paroxysmal AF ablation received pacing-synchronised high-frequency stimulation (HFS), delivered in SR during the left atrial refractory period, to compare ET-GP localisation between a custom-built current-controlled stimulator (Tau20) and a voltage-controlled stimulator (Grass S88, SIU5). Two patients with persistent AF underwent cardioversion, left atrial ET-GP mapping with the Tau20 and ablation (Precision™, Tacticath™ [n = 1] or Carto™, SmartTouch™ [n = 1]). Pulmonary vein isolation (PVI) was not performed. Efficacy of ablation at ET-GP sites alone without PVI was assessed at 1 year.

Results: The mean output to identify ET-GP was 34 mA (n = 5). Reproducibility of response to synchronised HFS was 100% (Tau20 vs Grass S88; [n = 16] [kappa = 1, SE = 0.00, 95% CI 1 to 1)][Tau20 v Tau20; [n = 13] [kappa = 1, SE = 0, 95% CI 1 to 1]). Two patients with persistent AF had 10 and 7 ET-GP sites identified requiring 6 and 3 min of radiofrequency ablation respectively to abolish ET-GP response. Both patients were free from AF for > 365 days without anti-arrhythmics.

Conclusions: ET-GP sites are identified at the same location by different stimulators. ET-GP ablation alone was able to prevent AF recurrence in persistent AF, and further studies would be warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-023-01517-9DOI Listing

Publication Analysis

Top Keywords

et-gp
13
left atrial
12
et-gp sites
12
ectopy-triggering ganglionated
8
persistent atrial
8
atrial fibrillation
8
et-gp localisation
8
stimulators et-gp
8
atrial et-gp
8
grass s88
8

Similar Publications

Background: Ablation of autonomic ectopy-triggering ganglionated plexuses (ET-GP) has been used to treat paroxysmal atrial fibrillation (AF). It is not known if ET-GP localisation is reproducible between different stimulators or whether ET-GP can be mapped and ablated in persistent AF. We tested the reproducibility of the left atrial ET-GP location using different high-frequency high-output stimulators in AF.

View Article and Find Full Text PDF

A 58-year-old woman with drug-refractory symptoms of paroxysmal atrial fibrillation (AF) was referred for AF ablation. A single site of ganglionated plexus triggering pulmonary vein ectopy and AF was ablated, without pulmonary vein isolation. This procedure led to long-term freedom from AF.

View Article and Find Full Text PDF

Background: Ganglionated plexuses (GPs) are implicated in atrial fibrillation (AF). Endocardial high-frequency stimulation (HFS) delivered within the local atrial refractory period can trigger ectopy and AF from specific GP sites (ET-GP). The aim of this study was to understand the role of ET-GP ablation in the treatment of AF.

View Article and Find Full Text PDF

The ectopy-triggering ganglionated plexuses in atrial fibrillation.

Auton Neurosci

November 2020

Myocardial Function Section, NHLI, Imperial College London, UK; Department of Cardiology, Imperial College Healthcare NHS Trust, London, UK; Imperial Centre for Cardiac Engineering, Imperial College London, London, UK. Electronic address:

Background: Epicardial ganglionated plexuses (GP) have an important role in the pathogenesis of atrial fibrillation (AF). The relationship between anatomical, histological and functional effects of GP is not well known. We previously described atrioventricular (AV) dissociating GP (AVD-GP) locations.

View Article and Find Full Text PDF

The autonomic nervous system is implicated in the multifactorial pathogenesis of atrial fibrillation (AF) but few studies have attempted neural targeting for therapeutic intervention. We have demonstrated that short bursts of stimulation, at specific sites of left atrial ganglionated plexi (GPs), trigger fibrillation-inducing atrial ectopy and importantly continuous stimulation of these sites may not induce AV block, the 'conventional' marker used to locate GPs. We have shown that these ectopy-triggering GP (ET-GP) sites are anatomically stable and can be rendered inactive by either ablation at the site or by ablation between the site and the adjacent pulmonary vein (PV).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!