Purpose: To evaluate the radiographic effect of quadriceps tendon harvest on patellar height and to determine whether closure of a quadriceps graft harvest defect resulted in a significant change in patellar height compared to nonclosure.

Methods: We conducted a retrospective review of prospectively enrolled patients. The institutional database was queried and all patients who underwent quadriceps autograft anterior cruciate ligament reconstruction between 2015 and March 2020 were included. Graft harvest length in millimeters and final graft diameter after preparation for implantation were obtained from the operative record and demographic data were obtained from the medical record. Radiographic analysis was performed of eligible patients using standard ratios of patellar height: Insall-Salvati (IS), Blackburn-Peele (BP), and Caton-Deschamps (CD). Measurements were performed using digital calipers on a digital imaging system by 2 postgraduate fellow surgeons. Preoperative and postoperative radiographs were performed at 0° according to a standard protocol. Postoperative radiographs were performed 6 weeks postoperatively in all cases. Preoperative patellar height ratios were compared with postoperative patellar height ratios for all patients using -tests. Subanalysis was then performed to compare the effect of closure of with nonclosure on patellar height ratios using repeated-measures analysis of variance. Interrater reliability between the 2 reviewers was assessed using an intraclass correlation coefficient calculation.

Results: In total, 70 patients met final inclusion criteria. There were no statistically significant changes from pre- to postoperative values for either reviewer for IS (reviewer 1,  = .47; reviewer 2,  = .353), BP (reviewer 1,  = .98; reviewer 2,  = .907), or CD (reviewer 1,  = .107; reviewer, 2  = .188). The closure and nonclosure groups were adequately powered and no statistically significant demographic differences between the closure and nonclosure groups was identified for sex ( = .066), age ( = .343), weight ( = .881), height ( = .42), laterality ( = 1), meniscal repair ( = .332), graft diameter ( = .068), or graft length ( = .183). According to the repeated measures analysis of variance, closure of the quadriceps defect had no significant impact on any of the knee ratios. However, reviewer identity had a significant influence on the CD ratio. Intraclass correlation coefficient analysis revealed excellent agreement between reviewers for the IS (0.982) and BP (0.954) ratios, but only moderate-to-good agreement for the CD (0.751) ratio.

Conclusions: Harvest of quadriceps tendon graft does not result in radiographic changes in patellar height. Furthermore, closure of the quadriceps defect does not appear to result in radiographic changes in patellar height.

Level Of Evidence: III, retrospective comparative trial.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9971865PMC
http://dx.doi.org/10.1016/j.asmr.2022.11.005DOI Listing

Publication Analysis

Top Keywords

patellar height
32
reviewer  =
24
 =
14
quadriceps tendon
12
closure quadriceps
12
height ratios
12
closure nonclosure
12
patellar
9
height
9
autograft anterior
8

Similar Publications

Background: It is known that open wedge high tibial osteotomy (OWHTO) may lead to progression of patellofemoral degeneration due to descent of the patellar height. However, the difference in patellofemoral joint (PFJ) loads with normal daily activity between uniplane and biplane osteotomies is unclear. The purpose of this study was to reveal the differences in PFJ biomechanics between uniplane and biplane OWHTO using finite element analysis (FEA).

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates whether the Insall-Salvati and Caton-Deschamps ratios align with normal distribution patterns in healthy knees, using data from 434 CT-scanned knees.
  • Results showed that while the Insall-Salvati ratio identified the 98th centile correctly for patella alta, it overdiagnosed patella baja, while the Caton-Deschamps index also revealed discrepancies in diagnosing patella baja at the 5th centile.
  • Overall, the study found poor inter-rater reliability between the two ratios, as indicated by a kappa coefficient of 0.01.
View Article and Find Full Text PDF

Background: Studies have revealed abnormalities of the epiphyseal plate of the distal femur in patients with trochlear dysplasia, but it is unclear whether the epiphyseal plate could be remodeled after surgical correction of patellar dislocation.

Purpose: To investigate whether the morphology of the epiphyseal plate and trochlea could be improved after medial patellar retinaculum plasty in skeletally immature patients and to investigate the correlations between the morphology of the epiphyseal plate and trochlear dysplasia as well as clinical outcomes.

Study Design: Cohort study; Level of evidence, 3.

View Article and Find Full Text PDF

Background: Hemophilic arthritis (HA) is associated with significant changes in the morphology of mature knee joints due to abnormal growth plate development. Previous studies have established marked distinctions between the femur and tibia of subjects with Haemophilia and those with osteoarthritis (OA). This study explored the morphological characteristics of the patella and patellofemoral joint in subjects with Haemophilia.

View Article and Find Full Text PDF

Background: Postoperative knee arthrofibrosis after arthroscopic ligament reconstruction is a serious complication. Among adolescents, risk factors for postoperative arthrofibrosis are not well characterized and the effectiveness of early manipulation under anesthesia (MUA) is not well established.

Purposes: To identify risk factors for arthrofibrosis after arthroscopic knee ligament reconstruction in adolescent patients and to evaluate the safety and effectiveness of early MUA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!