Pacemaker Site Dermatitis Neglecta: A Diagnostic Dilemma Unravelled by Dermoscopy.

Indian J Dermatol

Department of Dermatology, IMS and SUM Hospital, Bhubaneswar, Odisha, India E-mail:

Published: January 2022

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9971760PMC
http://dx.doi.org/10.4103/ijd.ijd_1043_21DOI Listing

Publication Analysis

Top Keywords

pacemaker site
4
site dermatitis
4
dermatitis neglecta
4
neglecta diagnostic
4
diagnostic dilemma
4
dilemma unravelled
4
unravelled dermoscopy
4
pacemaker
1
dermatitis
1
neglecta
1

Similar Publications

A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.

View Article and Find Full Text PDF

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.

View Article and Find Full Text PDF

Objective: To compare the paced QRS duration on different sites in age-, gender-, and indication-matched patients implanted with Micra leadless pacemakers and conventional transvenous pacemakers (TV-PM).

Method: A total of 82 patients from Xinhua Hospital, Shanghai Jiaotong University, were enrolled, including two groups of 41 patients matched according to gender, age, and pacemaker indications, who underwent Micra and TV-PM implantations, respectively. The baseline data of the patients, the pacing site described using three- and nine-partition methods, and the paced QRS duration on 12-lead electrocardiogram were then analyzed.

View Article and Find Full Text PDF

: An Unlikely Device-related Infection.

J Community Hosp Intern Med Perspect

January 2025

Department of Medicine, West Virginia University, House Staff 4Floor HSC-N Morgantown, PO Box 9168, Morgantown, WV, USA.

Implantable cardiac devices, including cardiac pacemakers, are not without risk for infection, carrying a mortality and morbidity of around 5-15%. Gram positive organisms are most common in 91% of cases, whereas gram negative organisms are less common, found in 2% of cases secondary to gram negative organisms other than . Here, we present a rare case of the gram-negative organism leading to a pacemaker site infection.

View Article and Find Full Text PDF

Purpose: Pacemaker-related infections are serious complications of cardiac implantable electronic devices (CIEDs). This case report aims to describe the occurrence of pacemaker pocket infection and recurrent ventricular tachycardia (VT) in a Chinese amateur violinist with sick sinus syndrome (SSS), and to explore the possible connection between occupational habits and the infection, as well as VT.

Methods: A 76-year-old male violinist with a Biotronik Evia DR dual-chamber pacemaker presented with syncope and signs of a pacemaker pocket infection three years after implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?