Purpose: The manual delineation of organs at risk is a process that requires a great deal of time both for the technician and for the physician. Availability of validated software tools assisted by artificial intelligence would be of great benefit, as it would significantly improve the radiation therapy workflow, reducing the time required for segmentation. The purpose of this article is to validate the deep learning-based autocontouring solution integrated in syngo.via RT Image Suite VB40 (Siemens Healthineers, Forchheim, Germany).

Methods And Materials: For this purpose, we have used our own specific qualitative classification system, RANK, to evaluate more than 600 contours corresponding to 18 different automatically delineated organs at risk. Computed tomography data sets of 95 different patients were included: 30 patients with lung, 30 patients with breast, and 35 male patients with pelvic cancer. The automatically generated structures were reviewed in the Eclipse Contouring module independently by 3 observers: an expert physician, an expert technician, and a junior physician.

Results: There is a statistically significant difference between the Dice coefficient associated with RANK 4 compared with the coefficient associated with RANKs 2 and 3 ( < .001). In total, 64% of the evaluated structures received the maximum score, 4. Only 1% of the structures were classified with the lowest score, 1. The time savings for breast, thorax, and pelvis were 87.6%, 93.5%, and 82.2%, respectively.

Conclusions: Siemens' syngo.via RT Image Suite offers good autocontouring results and significant time savings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9972393PMC
http://dx.doi.org/10.1016/j.adro.2023.101177DOI Listing

Publication Analysis

Top Keywords

siemens' syngovia
8
organs risk
8
syngovia image
8
image suite
8
coefficient associated
8
time savings
8
clinical validation
4
validation siemens'
4
syngovia automatic
4
automatic contouring
4

Similar Publications

Background: F-flutemetamol positron emission tomography (PET) is used to assess cortical amyloid-β burden in patients with cognitive impairment to support a clinical diagnosis. Visual classification is the most widely used method in clinical practice although semi-quantification is beneficial to obtain an objective and continuous measure of the Aβ burden. The aims were: first to evaluate the correspondence between standardized uptake value ratios (SUVRs) from three different software, Centiloids and visual classification, second to estimate thresholds for supporting visual classification and last to assess differences in semi-quantitative measures between clinical diagnoses.

View Article and Find Full Text PDF

Crohn's Disease Activity Quantified by Iodine Density Obtained From Dual-Energy Computed Tomography Enterography.

J Comput Assist Tomogr

April 2020

From the NYU Langone Health Departments of Radiology and Gastroenterology New York, NY.

Objective: The objective of this study was to assess if bowel wall iodine density obtained from dual-source, dual-energy computed tomography enterography (DECTE) could be a biomarker of Crohn's disease activity.

Methods: Twenty-two patients with Crohn's disease imaged with DECTE from February 2016 to May 2018 were retrospectively identified by departmental report search. Iodine maps were created with commercial software (Syngovia).

View Article and Find Full Text PDF

We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, and patients (n = 10) with verified cardiac shunts in this retrospective study.

View Article and Find Full Text PDF

Background: Patent ductus arteriosus (PDA) stent placement in infants with ductal-dependent pulmonary blood flow is being increasingly used in clinical practice.

Objective: To correlate computed tomographic (CT) angiography morphology and length of the PDA with catheter angiography and its relation to eventual PDA stent length.

Materials And Methods: We retrospectively identified all pediatric patients who underwent PDA stenting at our institute from 2004 to 2018.

View Article and Find Full Text PDF

Purpose: The aim of the study was to evaluate the usefulness and accuracy of 18-fluorine-labeled fluorodeoxyglucose (PET) and magnetic resonance imaging (MRI) hybrid in gross tumor volume (GTV) delineation during radiotherapy planning in patients with carcinoma of the tongue.

Methods: Ten patients with squamous cell carcinoma (SCC) of the tongue underwent computed tomography (CT) and PET/MRI examination. The GTV for primary tumor and lymph nodes (nGTV) were defined on CT (GTV-CT) and compared to GTVs obtained from PET (GTV-PET) and MRI (GTV-MRI) images.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!