AI Article Synopsis

  • This study assesses the rate of postoperative meningitis in patients who receive cochlear implants (CIs) through a systematic review and meta-analysis of existing literature.
  • A total of 116 studies were included, revealing that out of 58,940 patients, there were 112 cases of meningitis, resulting in an estimated incidence rate of 0.07%.
  • The findings suggest that meningitis is a rare complication following CIs, with lower rates than earlier studies, especially in patients who received preventive measures like vaccinations and antibiotics.

Article Abstract

Objective: This study aims to estimate the rate of postoperative meningitis (both immediate and long-term) in patients following cochlear implants (CIs). It aims to do so through a systematic review and meta-analysis of published studies tracking complications after CIs.

Data Sources: MEDLINE, Embase, and Cochrane Library.

Review Methods: This review was performed in line with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies tracking complications following CIs in patients were included. Exclusion criteria included non-English language studies and case series reporting <10 patients. Bias risk was evaluated using the Newcastle-Ottawa Scale. Meta-analysis was performed through DerSimonian and Laird random-effects models.

Results: A total of 116/1931 studies met the inclusion criteria and were included in the meta-analysis. Overall, there were 112 cases of meningitis in 58,940 patients after CIs. Meta-analysis estimated an overall rate of postoperative meningitis of 0.07% (95% confidence interval [CIs], 0.03%-0.1%; I  = 55%). Subgroup meta-analysis showed this rate had 95% CIs crossing 0% in implanted patients who received the pneumococcal vaccine, antibiotic prophylaxis, those with postoperative acute otitis media (AOM), and those implanted less than 5 years.

Conclusion: Meningitis is a rare complication following CIs. Our estimated rates of meningitis after CIs appear lower than prior estimates based on epidemiological studies in the early 2000s. However, the rate still appears higher than the baseline rate in the general population. The risk was very low in implanted patients who received the pneumococcal vaccine, antibiotic prophylaxis, received unilateral or bilateral implantations, developed AOM, those implanted with a round window or cochleostomy techniques, and those under 5 years.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ohn.309DOI Listing

Publication Analysis

Top Keywords

systematic review
8
review meta-analysis
8
studies tracking
8
tracking complications
8
risk meningitis
4
meningitis cochlear
4
cochlear implantation
4
implantation systematic
4
meta-analysis objective
4
objective study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!