Development of an efficient method for selection of stable cell pools for protein expression and surface display with Expi293F cells.

Cell Biochem Funct

Division of Infectious Diseases, Department of Medicine, Center for Antibody Therapeutics, University of Pittsburgh Medical School, Pittsburgh, Pennsylvania, USA.

Published: April 2023

Compare with transient expression, stable cell lines generally have higher productivity and better quality for protein expression. However, selection of stable cell line is time-consuming and laborious. Here we describe an optimized selection method to achieve high-efficient stable cell pools with Expi293F suspension cells. This method only takes 2-3 weeks to generate stable cell pools with 2- to 10-fold higher productivity than transient gene expression (TGE). In fed-batch culture with Yeastolate, >1 g/L yield was achieved with our KTN0239-IgG stable cell pool in shaker flasks. This method can be also applied to efficiently display proteins on the cell surface.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cbf.3787DOI Listing

Publication Analysis

Top Keywords

stable cell
24
cell pools
12
selection stable
8
protein expression
8
higher productivity
8
cell
7
stable
6
development efficient
4
method
4
efficient method
4

Similar Publications

In overcoming the barrier of rapid Li transfer in lithium-ion batteries at extreme temperatures, the desolvation process and interfacial charge transport play critical roles. However, tuning the solvation structure and designing a kinetically stable electrode-electrolyte interface to achieve high-rate charging and discharging remain a challenge. Here, a lithium nonafluoro-1-butanesulfonate (NFSALi) additive is introduced to optimize stability and the robust solid electrolyte interface film (SEI), realizing a rapid Li transfer process and the structural integrity of electrode materials.

View Article and Find Full Text PDF

Background: Most patients initially diagnosed with non-muscle invasive bladder cancer (NMIBC) still have frequent recurrence after urethral bladder tumor electrodesiccation supplemented with intravesical instillation therapy, and their risk of recurrence is difficult to predict. Risk prediction models used to predict postoperative recurrence in patients with NMIBC have limitations, such as a limited number of included cases and a lack of validation. Therefore, there is an urgent need to develop new models to compensate for the shortcomings and potentially provide evidence for predicting postoperative recurrence in NMIBC patients.

View Article and Find Full Text PDF

Introduction: The transition to electric vehicles (EVs) has highlighted the need for efficient diagnostic methods to assess the state of health (SoH) of lithium-ion batteries (LIBs) at the end of their life cycle. Electrochemical Impedance Spectroscopy (EIS) offers a non-invasive technique for determining battery degradation. However, automating this process in industrial settings remains a challenge.

View Article and Find Full Text PDF

Polysorbates degrading enzymes in biotherapeutics - a current status and future perspectives.

Front Bioeng Biotechnol

January 2025

Pharmaceutical Development Biologicals, TIP, Boehringer Ingelheim Pharma GmbH & Co., KG, Innovation Unit, Biberach an der Riss, Germany.

Polysorbates, in particular polysorbate (PS) 20 and 80, are the most commonly used surfactants for stabilising biotherapeutics produced by biotechnological processes. PSs are derived from ethoxylated sorbitan (a derivative of sorbitol) esterified with fatty acids of varying chain length and degree of saturation. In the past, these surfactants have been reported to have specific liabilities.

View Article and Find Full Text PDF

The growing demand for efficient, stable, and environmentally friendly photovoltaic technologies has motivated the exploration of nontoxic perovskite materials such as KGeCl. However, the performance of KGeCl-based perovskite solar cells (PSCs) depends heavily on the compatibility of charge transport layers (CTLs) and optimization of device parameters. In this study, six PSC configurations were simulated using SCAPS-1D software, incorporating CTLs such as Alq, CSTO, VO, PB, and SbS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!