Wireless monitoring devices in hospitalized children: a scoping review.

Eur J Pediatr

Division of Experimental Medicine, Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada.

Published: May 2023

The purpose of this study is to provide a structured overview of existing wireless monitoring technologies for hospitalized children. A systematic search of the literature published after 2010 was conducted in Medline, Embase, Scielo, Cochrane, and Web of Science. Two investigators independently reviewed articles to determine eligibility for inclusion. Information on study type, hospital setting, number of participants, use of a reference sensor, type and number of vital signs monitored, duration of monitoring, type of wireless information transfer, and outcomes of the wireless devices was extracted. A descriptive analysis was applied. Of the 1130 studies identified from our search, 42 met eligibility for subsequent analysis. Most included studies were observational studies with sample sizes of 50 or less published between 2019 and 2022. Common problems pertaining to study methodology and outcomes observed were short duration of monitoring, single focus on validity, and lack information on wireless transfer and data management.  Conclusion: Research on the use of wireless monitoring for children in hospitals has been increasing in recent years but often limited by methodological problems. More rigorous studies are necessary to establish the safety and accuracy of novel wireless monitoring devices in hospitalized children. What is Known: • Continuous monitoring of vital signs using wired sensors is the standard of care for hospitalized pediatric patients. However, the use of wires may pose significant challenges to optimal care. What is New: • Interest in wireless monitoring for hospitalized pediatric patients has been rapidly growing in recent years. • However, most devices are in early stages of clinical testing and are limited by inconsistent clinical and technological reporting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9977642PMC
http://dx.doi.org/10.1007/s00431-023-04881-wDOI Listing

Publication Analysis

Top Keywords

wireless monitoring
20
hospitalized children
12
wireless
8
monitoring devices
8
devices hospitalized
8
vital signs
8
duration monitoring
8
wireless transfer
8
hospitalized pediatric
8
pediatric patients
8

Similar Publications

Real-time monitoring of hemodynamics is crucial for diagnosing disorders within implanted vascular grafts and facilitating timely treatment. Integrating vascular grafts with advanced flexible electronics offers a promising approach to developing smart vascular grafts (SVGs) capable of continuous hemodynamic monitoring. However, most existing SVG devices encounter significant challenges in practical applications, particularly regarding biomechanical compatibility and the effective evaluation of vascular status.

View Article and Find Full Text PDF

Muscle Fiber-Inspired High-Performance Strain Sensors for Motion Recognition and Control.

Langmuir

January 2025

Henan Province Engineering Technology Research Center of MEMS Manufacturing and Applications, School of Mechanics and Safety Engineering, Zhengzhou University, Zhengzhou 450001, China.

The rapid development of wearable technology, flexible electronics, and human-machine interaction has brought about revolutionary changes to the fields of motion analysis and physiological monitoring. Sensors for detecting human motion and physiological signals have become a hot topic of current research. Inspired by the muscle fiber structure, this paper proposed a highly stable strain sensor that was composed of stretchable Spandex fibers (SPF), multiwalled carbon nanotubes (MWCNTs), and silicone rubber (Ecoflex).

View Article and Find Full Text PDF

System-level wearable electronics require to be flexible to ensure conformal contact with the skin, but they also need to integrate rigid and bulky functional components to achieve system-level functionality. As one of integration methods, folding integration offers simplified processing and enhanced functionality through rigid-soft region separation, but so far, it has mainly been applied to modality of electrical sensing and stimulation. This paper introduces a vialess heterogeneous skin patch with multi modalities that separates the soft region and strain-robust region through folded structure.

View Article and Find Full Text PDF

Olfactory-Inspired Separation-Sensing Nanochannel-Based Electronics for Wireless Sweat Monitoring.

ACS Nano

January 2025

CAS Key Laboratory of Bio-inspired Materials and Interfacial Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, P.R. China.

Human sweat has the potential to be sufficiently utilized for noninvasive monitoring. Given the complexity of sweat secretion, the sensitivity and selectivity of sweat monitoring should be further improved. Here, we developed an olfactory-inspired separation-sensing nanochannel-based electronic for sensitive and selective sweat monitoring, which was simultaneously endowed with interferent separation and target detection performances.

View Article and Find Full Text PDF

The explosion of Internet-of-Thing enables several interconnected devices but also gives rise chance for unauthorized parties to compromise sensitive information through wireless communication systems. Covert communication therefore has emerged as a potential candidate for ensuring data privacy in conjunction with physical layer transmission to render two lines of defense. In this paper, we aim to enhance the individual transmission of nearby users in non-orthogonal multiple access (NOMA) systems under scenarios of an eavesdropper who monitors covert transmission before decoding covert information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!