High-energy resolution core-level spectroscopies, including a group of different techniques to obtain element-specific information of the electronic structure around an absorption site, have become powerful tools for studying the chemical state, local geometric structure, and the nature of chemical bonding. High-resolution x-ray absorption and x-ray emission spectroscopies are well-established experimental techniques but have always been limited by the number of emitted photons and the limited acceptance of solid angles, as well as requiring high energy stability and repeatability for the whole experimental setup. A full-cylindrical x-ray spectrometer based on flexible HAPG (highly annealed pyrolitic graphite) mosaic crystals is an effective solution for the above issues. However, large-area HAPG remains expensive and is often not easy to access. Here, we present an alternative approach by using segmented single crystals (Si and Ge) with different orientations instead of the HAPG as a dispersive element. The proposed method drastically improved the energy resolution up to 0.2-2 eV in the range of 2-10 keV. High-pressure x-ray emission and resonant x-ray emission spectra are presented to demonstrate the capabilities of the instrument. The new design is particularly suitable for high-resolution spectroscopy applications at fourth-generation synchrotron radiation sources or free-electron lasers.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0133896DOI Listing

Publication Analysis

Top Keywords

x-ray emission
12
spectrometer based
8
x-ray
6
von hamos
4
hamos full-cylindrical
4
full-cylindrical spectrometer
4
based striped
4
striped si/ge
4
si/ge crystal
4
crystal advanced
4

Similar Publications

Introduction: Identifying early risks of developing Alzheimer's disease (AD) is a major challenge as the number of patients with AD steadily increases and requires innovative solutions. Current molecular diagnostic modalities, such as cerebrospinal fluid (CSF) testing and positron emission tomography (PET) imaging, exhibit limitations in their applicability for large-scale screening. In recent years, there has been a marked shift toward the development of blood plasma-based diagnostic tests, which offer a more accessible and clinically viable alternative for widespread use.

View Article and Find Full Text PDF

3D Printing of a Self-Healing, Bioactive, and Dual-Cross-Linked Polysaccharide-Based Composite Hydrogel as a Scaffold for Bone Tissue Engineering.

ACS Appl Bio Mater

January 2025

Advanced Magnetic Materials Research Center, School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, North Kargar Street, Tehran 11155-4563, Iran.

Although 3D printing is becoming a dominant technique for scaffold preparation in bone tissue engineering (TE), developing hydrogel-based ink compositions with bioactive and self-healing properties remains a challenge. This research focuses on developing a bone scaffold based on a composite hydrogel, which maintains its self-healing properties after incorporating bioactive glass and is 3D-printable. The plain hydrogel ink was synthesized using natural polymers of 1 wt % N-carboxyethyl chitosan, 2 wt % hyaluronic acid aldehyde, 0.

View Article and Find Full Text PDF

Background Fracture of nickel-titanium (Ni-Ti) instruments in root canals is commonly associated with compromised outcomes in endodontic treatment. There is no single, universally accepted approach for managing this complication. The objective of this study is to evaluate the effectiveness of an Nd: YAP laser-assisted protocol in removing fractured Ni-Ti files in teeth with minimal root curvature (less than 15 degrees).

View Article and Find Full Text PDF

In this study, we attempt to illustrate fossil vertebrate dental tissue geochemistry and, by inference, its extent of diagenetic alteration, using quantitative, semi-quantitative and optical tools to evaluate bioapatite preservation. We present visual comparisons of elemental compositions in fish and plesiosaur dental remains ranging in age from Silurian to Cretaceous, based on a combination of micro-scale optical cathodoluminescence (CL) observations (optical images and scanning electron microscope) with minor, trace and rare earth element (REE) compositions (EDS, maps and REE profiles), as a tool for assessing diagenetic processes and biomineral preservation during fossilization of vertebrate dental apatite. Tissue-selective REE values have been obtained using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), indicating areas of potential REE enrichment, combined with cathodoluminescence (CL) analysis.

View Article and Find Full Text PDF

Case report: Detecting giant cell arteritis in [Ga]Ga-DOTA-Siglec-9-PET/CT.

Front Immunol

January 2025

Department of Rheumatology and Clinical Immunology, Clinic of Internal Medicine III, University Hospital Bonn, Bonn, Germany.

Objectives: This study aimed to evaluate the diagnostic utility of [Ga]Ga-DOTA-Siglec-9 positron emission tomography-computed tomography (PET/CT) in assessing disease activity in a patient experiencing a relapse of giant cell arteritis (GCA).

Case Presentation: A 90-year-old male patient with GCA, diagnosed in 2018, was enrolled. Demographic data, disease history, and laboratory parameters, including soluble VAP-1 (sVAP-1) levels, were recorded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!